![Extraflame ANGELA User Manual Download Page 11](http://html.mh-extra.com/html/extraflame/angela/angela_user-manual_2454224011.webp)
ENGLISH
DuCtInG spECIFICAtIons oF AnGElA plus
The Angela Plus model is fitted with 1 ducting outlet.
features:
diameter of ducting outlet: 80 mm
maximum recommended ducting length 8m
temperature controlled ducting
regulation of air flow speed as a percentage
independent ducting that can be activated/deactivated (On-Off)
REARMInG
If tripped, it is recommended to contact a qualified technician to
determine the cause.
FusE
If there is no power supply to the stove, check the state of the fuse
located in the box between the stove switch and the power cable
connection.
InstAllAtIon Must BE pERFoRMED By quAlIFIED stAFF AnD/oR tHE MAnuFACtuRER's AFtER-sAlEs
tECHnICIAns.
usE oF supplEMEntARy tHERMostAt to ContRol DuCtInG MotoR
In models with a ducting motor, the motor itself can also be controlled by the thermostat. When an external thermostat is connected, the
ducting motor can be controlled independently of stove operation.
At this point, simply set the desired temperature on the external thermostat:
until the temperature is reached (closed contact) the ducting motor will follow the stove settings.
when the temperature is reached (open contact), the ducting motor will work at minimum speed.
The terminal for the ducting thermostat is supplied standard with a jumper.
The ducting extension is found in the accessory pack inside the
stove. It is mounted by means of the 4 supplied screws.