background image

ENGLISH

Warnings

This instructions manual is an integral part of the product: make sure that it always accompanies the 

appliance, even if transferred to another owner or user, or if transferred to another place. If it is damaged 

or lost, request another copy from the area technician. This product is intended for the use for which it 

has been expressly designed. The manufacturer is exempt from any liability, contractual and extracon-

tractual, for injury/damage caused to persons/animals and objects, due to installation, adjustment and 

maintenance errors and improper use.

Installation must be performed by qualified staff, which assumes complete responsibility for the de-

finitive installation and consequent good functioning of the product installed. One must also bear in 

mind all laws and national, regional, provincial and town council Standards present in the country in 

which the appliance has been installed, as well as the instructions contained in this manual.

The Manufacturer cannot be held responsible for the failure to comply with such precautions.

After removing the packaging, ensure that the content is intact and complete. Otherwise, contact the 

dealer where the appliance was purchased.

All electric components that make up the product must be replaced with original spare parts exclusively 

by an authorised after-sales centre, thus guaranteeing correct functioning.

safety

 

Š

THE APPLIANCE MAY BE USED BY CHILDREN 8 YEARS OF AGE OR OLDER AND INDIVIDUALS 

WITH REDUCED PHYSICAL, SENSORY, OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR 

THE NECESSARY KNOWLEDGE, PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED 

INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT 

DANGERS.

 

Š

THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED 

PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY 

ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE 

FOR THEIR SAFETY.

 

Š

THE CLEANING AND MAINTENANCE REQUIRED BY THE USER MUST NOT BE PERFORMED BY 

CHILDREN WITHOUT SUPERVISION.

 

Š

CHILDREN MUST BE CHECKED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.

 

Š

DO NOT TOUCH THE GENERATOR WHEN YOU ARE BAREFOOT OR WHEN PARTS OF THE BODY 

ARE WET OR DAMP.

 

Š

THE SAFETY AND ADjUSTMENT DEVICES MUST NOT BE MODIFIED WITHOUT THE AUTHORISATION 

OR INDICATIONS OF THE MANUFACTURER.

 

Š

DO NOT PULL, REMOVE, TWIST THE ELECTRICAL CABLES COMING OUT OF THE PRODUCT EVEN 

IF IT IS DISCONNECTED FROM THE MAINS.

 

Š

IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO 

CONTACT WITH HOT PARTS OF THE APPLIANCE.

 

Š

THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTER INSTALLATION.

 

Š

DO NOT CLOSE OR REDUCE THE DIMENSIONS OF THE AIRING VENTS IN THE PLACE OF 

INSTALLATION. THE AIRING VENTS ARE ESSENTIAL FOR CORRECT COMBUSTION.

 

Š

DO NOT LEAVE THE PACKAGING ELEMENTS WITHIN REACH OF CHILDREN OR UNASSISTED 

We thank you for having chosen our company; our product is a great heating solution developed from the 

most advanced technology with top quality machining and modern design, aimed at making you enjoy the 

fantastic sensation that the heat of a flame gives, in complete safety.

5

Summary of Contents for 001282600

Page 1: ...MADE IN ITALY design production VIRNA IDRO 004276851 rev 002 UK THERMO PRODUCTS USER MANUAL...

Page 2: ...ENGLISH 2...

Page 3: ...hermostat 21 Additional thermostat functioning with STAND BY active 21 Additional thermostat operation with STAND BY deactivated 21 Additional thermostat installation 21 easy setup 22 CHRONO 22 Enabli...

Page 4: ...IMP RATIF Avant de d placer le po le retirer le rev tement indiqu pour viter tout dommage ACHTUNG PFLICHT Bevor der Ofen bewegt wird muss die angezeigte Verkleidung entfernt werden um Sch den zu verme...

Page 5: ...ITH REDUCED PHYSICAL SENSORY OR MENTAL CAPACITIES OR WITHOUT EXPERIENCE OR THE NECESSARY KNOWLEDGE PROVIDED THAT THEY ARE SUPERVISED OR HAVE RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT...

Page 6: ...r ignition During the filling phase do not put the bag of pellets to into contact with the product The majolicas aretop quality artisan products and as such can have micro dots crackles and chromatic...

Page 7: ...at the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation For installation in a condominium prior approval from the condominium s...

Page 8: ...lection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duc...

Page 9: ...for passive houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly con...

Page 10: ...and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation mus...

Page 11: ...harge into the flue This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre e...

Page 12: ...output T3 Boiler return input Virna IDRO details Combustive air rear inlet Lower fumes exhaust Upper fumes exhaust Combustive air side inlet Pellet hopper pressurised closure Heat exchanger scrapers E...

Page 13: ...conveying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenome...

Page 14: ...gnitionthestovewillgointo DEPRALARM mode while during normal operation the stove will go into COOLING WAITING TIME mode and then re start automatically when the correct conditions are present stove co...

Page 15: ...be seasoned in order to obtain a sufficiently adequate heat yield THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND CAN VOID THE WARRANTY AND THE ANNEXED...

Page 16: ...external additional thermostat is closed and the STAND BY function is enabled Flashing with contact open the contact of the external additional thermostat is open and the STAND BY function is enabled...

Page 17: ...must be followed the first times the stove is ignited It is possible that slight odours are produced due to the drying of the paints and silicone used Do not remain in the room for long periods Do not...

Page 18: ...15 Decrease Decreases the value displayed 16 Stove status Displays the general status of the stove Battery type and replacement The battery is housed in the lower part of the remote control To replac...

Page 19: ...d key 1 to return to the previous menus to the initial state Language This menu allows the preferred language to be selected The languages available are Italiano English German French Spanish Portugue...

Page 20: ...d the stove will re start automatically and continue the working phase returning to the selected power level MODULATION and H OFF As the water temperature approaches the set point the boiler starts to...

Page 21: ...inside the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operati...

Page 22: ...ENOUGH Controls procedure Press key 6 Press key 3 until easy setup appears and confirm by pressing key 6 Use keys 4 and 5 to set the range Press key 6 to confirm and key 1 to return to the previous m...

Page 23: ...FF 00 00 PRG1 stop time Monday Sunday On off Enabling disabling days for PRG1 Set prg1 65 C 80 C 149 F 176 F Set thermostat PRG1 Power prg1 1 5 Set power PRG1 prg2 Start prg2 OFF 00 00 PRG2 start time...

Page 24: ...02 00 23 00 08 00 16 30 t 02 00 23 00 08 00 16 30 t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 Time slot 1 start 02 00 stop 23 00 power 3 set temp 72 C Time slot 2 start 08 00 stop 16 30 power 1 set tem...

Page 25: ...via an additional thermostat Controls procedure Press key 6 Press key 3 until SETTINGS appears and confirm by pressing key 6 Continue by pressing key 3 until STAND BY appears and confirm by pressing k...

Page 26: ...Press 3 until SETTINGS appears and confirm by pressing 6 Press key 3 until OUTLET AIR appears and confirm by pressing key 6 Use keys 4 and 5 for enabling ON or disabling OFF Press key one several time...

Page 27: ...use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspa...

Page 28: ...burn pot using the poker supplied Re position the burn pot in its seat and push it towards the fire wall Replace the pellet chute assembly on the burn pot Make sure that the burn pot and pellet chute...

Page 29: ...ENGLISH EVERY 30 DAYS Cleaning the combustion chamber deflector Remove the deflector and eliminate the ash deposited in the upper part of the deflector 29...

Page 30: ...physically and a pellet chute assembly B When cleaning and removing the burn pot remove the pellet chute assembly B by lifting it see figure Perform the same operation in reverse order to re assemble...

Page 31: ...product warranty GASKETS pellet hopper lid DOOR ASH DRAWER AND BURN POT The gaskets guarantee the tightness of the stove and its consequent good functioning They must be controlled periodically They m...

Page 32: ...let hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleani...

Page 33: ...llet hopper ash drawer and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and clean...

Page 34: ...it will re start automatically Anti freeze The anti freeze function is in progress as the H2O temperature is below the factory set threshold the pump is active until the water reaches the pre set fact...

Page 35: ...tre MAX H20 PRESSURE ALARM Air in the system Inadequate circulation Possible air in the system bleed the system Lack of adequate circulation Lack of or inadequate safety zone The water in the stove ha...

Page 36: ...ity to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarant...

Page 37: ...t pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product...

Page 38: ...ENGLISH 38...

Page 39: ...ENGLISH 39...

Page 40: ...lame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufacturer reserves the right to vary the char...

Reviews: