Section 904
Accelerometer TL-3424_EXT
Page Date: 19. February 2014
904 - 5
Pilot´s Operating Handbook US
EXTRA 330LX
The TL-3424_EXT checks all measured values at two levels - for a warning and an alarm limit
signalization. If the measured values are above the warning limit and below the alarm limit an
intermitted sound is heard on the head set and the G/V LIMIT WARNING LIGHT flashes. If the
measured value exceeds the alarm limit a continuous sound is heard on the head set and the G/V
LIMIT WARNING LIGHT illuminates continuously.
When the alarm warning has been activated, the instrument will display a service message after
the next turn-on of the instrument to inform the user of the exceeded acceleration.
The USER BUTTON is programmed in the main set-up to display the minimum and maximum
acceleration overview.
MEMORY
The following memory types are included in the TL-3424_EXT:
1.) A long-term memory storing the last recorded ~30 minutes (20,000 lines, entries every 0.1
seconds).
2.) A „Scheck“-Report storing all cases of limit exceedance and the values in the immediate vicinity
of this event (160 lines per case).
3.) A Line Report storing the last 64 values of limit exceedance (acceleration and speed).
A rolling type memory is used. This means, that in case the available memory capacity is
exceeded, the oldest memory lines will be overwritten.
PRESETTINGS
The following values or definitions are preset in the configuration of the TL-3424_EXT:
WARNING MAX
+9.5 g
WARNING MIN
-9.5 g
ALARM MAX
+10.1 g
ALARM MIN
-10.1 g
SPEED LIMIT
220 KIAS
Record begins at 50 KIAS
LANGUAGE
English
SAMPLE RATE
0.1
Summary of Contents for 330lx