After 2000 operating hours or at 12‐month intervals
Check the water separator of the pressurized air system. The water separator is located
beside the pressurized air connection.
You must replace any filter that has damage to its external surface, or if the suction
effect is weak even after cleaning
Check the control filter, and vacuum away any dust that has accumulated on the
external surface. If the filter surface is very dirty, the filter must be replaced with a new
one.
Check the condition of lines and pressure hoses as well as connections.
Make sure that the fastening latches are tight; tighten if necessary.
After 1000 operating hours or at six‐month intervals
Make sure that the cleaning system is functioning properly. The opening and closing
sound of cut-off valves can be heard 9 times. Impulse valves give pressure impacts in
every 10 seconds.
Inspect, clean and lubricate the seals.
MAINTENANCE INSTRUCTIONS
-
All maintenance points must be
inspected regularly to ensure that the
suction unit operates as planned.
-
Maintenance frequency depends on the
quantity and composition of filtered
materials.
-
Damaged and worn parts should be
replaced immediately for new parts.
WARNING
-
Disconnect the device from mains
supply before carrying out maintenance
work.
-
Use the safety lock.
-
Use safety goggles, a respirator and
safety gloves when servicing, operating
or repairing the equipment.
-
Shut off compressed air supply and
discharge pressure from the system
before starting with maintenance
works.