9                                                      SDL470-en-GB_v1.4   3/17 

Datalogging and PC Interface 

Types of Data Recording 

 

Manual Datalogging:

 Manually log up to 99 readings onto an SD card via push-button press. 

 

Automatic Datalogging:

 Automatically log data onto an SD memory card where the number 

of data points is virtually limited only by the card size. Readings are logged at a rate specified 

by the user. 

SD Card Information 

 

Insert an SD card (from 1G size up to 16G; however 4GB sized cards or smaller are 

recommended) into the SD card slot at the bottom of the meter. The card must be inserted 

with the front of the card (label side) facing toward the rear of the meter. 

 

If the SD card is being used for the first time it is recommended that the card be formatted 

and the logger’s clock set to allow for accurate date/time stamping during Datalogging 

sessions. Refer to the Setup Mode section for SD card formatting and time/date setting 

instructions. 

 

European and USA numerical formats differ. The data on the SD card can be formatted for 

either format. The meter defaults to USA mode where a decimal point is used to separate 

units from tenths, i.e. 

20.00

. The European format uses a comma, i.e. 

20,00

. To change this 

setting, refer to the Setup Mode section. 

Manual Datalogging 

In the manual mode the user can manually log one reading at a time onto the SD card (up to 99 

readings). 
1.

 

Set the sampling rate to ‘0’ seconds as described in the Setup Mode section. 

2.

 

Press and hold the LOGGER button for at least 2 seconds (the LOGGER icon will appear). 

3.

 

If an SD card is not installed in the meter, the display will show an error message (CARD). 

4.

 

In an SD card is installed, the lower portion of the display will show P-

n

 (

n

 = memory 

position number 1-99).  

5.

 

Use the 

 and 

 buttons to select one of the 99 data memory positions in which to 

record.  

6.

 

Short press the LOG button to store the reading (the SCAN CARD display icon will show 

briefly as the reading is stored in the selected location). Repeat steps 5 and 6 for up to 99 

readings. 

7.

 

To exit the manual Datalogging mode, press and hold the LOG button for at least 2 seconds. 

The P

n

 and LOGGER icons will switch off. 

Summary of Contents for SDL470

Page 1: ...USER MANUAL UVA UVC Light Meter with Temperature Model SDL470 ...

Page 2: ... with cosine correction filter UV Zero feature Applications include Monitoring blue light radiation from welding equipment UV sterilization graphic arts photochemical matching UV EPROM erasure Photo resist exposure ink curing adhesives and coatings Microprocessor circuit provides high reliability and durability Separate UV light probe allows the user to measure UV light with optimum positioning Ty...

Page 3: ... Date Check and SET button 8 ENTER and LOG button 9 Side compartment detailed below 10 UVA Probe and UVC Probe input plug 11 Type K J thermocouple socket 12 SD Card Slot 13 UVC sensor 14 UVA probe handle 15 UVA sensor protective cover not shown Note Battery compartment tilt stand and tripod mount are located on rear of meter 1 DC 9V power adaptor jack 2 Reset button 3 RS 232 output port ...

Page 4: ... show the µW cm 2 unit of measure The meter is now ready to make UVA light measurements Holding the Sensor Handle face the UVA Sensor toward the source of UVA light The display will show the measurement reading UVC Light Meter Insert the UVC Probe Plug into the Probe Input Socket Switch the meter ON by pressing and holding the Power button for at least 2 seconds Select the UVC Light Meter option a...

Page 5: ...LD display icon will switch OFF MAX MIN Reading Store Recall For a given measurement session this meter can record the highest MAX and the lowest MIN readings Press the MAX MIN button momentarily REC icon appears The meter is now recording the MAX and MIN readings Press the MAX MIN button again to view the current MAX readings MAX icon appears The readings on the display are now the highest readin...

Page 6: ...d below Additional detailed information is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds SP t Set the datalogger sampling rate 1 2 5 10 30 60 120 300 600 1800 3600 seconds PoFF Auto power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 Sd F Format...

Page 7: ... If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Set the Beeper Sound ON or OFF bEEP 1 From the bEEP parameter window use the arrow buttons to select ON enable or OFF disable 2 Press ENTER to confirm setting and to move to the next parameter 3 If desired press and hold the SET button for 2 seconds to ...

Page 8: ... the next parameter 3 If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Set the Thermocouple Type K or J tYPE 1 From the tYPE parameter screen use the arrow buttons to select the desired sensor type 2 Press ENTER to confirm setting and to move to the next parameter 3 If desired press and hold the SET bu...

Page 9: ... The data on the SD card can be formatted for either format The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 To change this setting refer to the Setup Mode section Manual Datalogging In the manual mode the user can manually log one reading at a time onto the SD card up to 99 readings 1 Set the sampling r...

Page 10: ...d is not inserted or if the card is defective the meter will display a CARD error In this case switch the meter OFF and try again with a valid SD card 6 Pause the datalogger by short pressing the LOG button The REC icon will switch OFF To resume logging short press the LOG button again 7 To terminate the Datalogging session press and hold the LOG button for at least 2 seconds 8 When an SD card is ...

Page 11: ... available at most outlets where computer accessories are sold 4 Power on the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example RS 232 USB PC Interface For streaming of data to a PC via the RS232 Output jack 3 5mm the optional 407001 USB kit RS232 to USB cable and driver CD along...

Page 12: ...ter 5 Note that the time and date must be reset when the batteries are replaced see the SETUP Mode section of this user guide Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dis...

Page 13: ...S 232 USB PC interface Operating Temperature 0o C to 50o C 32o F to 122o F Operating Humidity Less than 85 RH Power Supply Alkaline 1 5V AA batteries x 6 or 9V AC adaptor UA100 240 Power Consumption Normal operation without SD storing and with display backlight OFF 6 5mA DC approx With SD card storing but display backlight OFF 30mA DC approx With the LCD backlight ON the power consumption increase...

Page 14: ... K J Thermocouple Thermometer Sensor type Resolution Range Accuracy Type K 0 1C 50 0 to 1300 0o C 50 1 to 100 0o C 0 2 0 5o C 0 2 1 0o C 0 1F 58 0 to 2372 0oF 58 1 to 148 0o F 0 2 1 0oF 0 2 1 8o F Type J 0 1C 50 0 to 1100 0oC 50 1 to 100 0o C 0 2 0 5oC 0 2 1 0o C 0 1F 58 0 to 2012 0o F 58 1 to 148 0o F 0 2 1 0o F 0 2 1 8o F Note Above specifications tested with an RF strength less than 3V M and a ...

Reviews: