Extech Instruments RHT30 User Manual Download Page 3

3

                                  

RHT30_TH30

en

GB_V1.0

    

(11/16)

 

5.

 

Status

 

LED

 

indicator

 

(red/green).

 

Refer

 

to

 

the

 

Status

 

LED

 

Indicator

 

Description

 

later

 

in

 

this

 

section.

 

6.

 

MAX

MIN

 

button.

 

Refer

 

to

 

the

 

Button

 

Descriptions

 

later

 

in

 

this

 

section.

 

7.

 

Sensors

 

(Thermistor

 

internal

 

air

 

temperature

 

and

 

capacitive

 

RH

 

sensor)

 

8.

 

Power

 

and

 

Datalog

 

Start/Stop

 

button.

 

Refer

 

to

 

the

 

Button

 

Descriptions

 

later

 

in

 

this

 

section.

  

9.

 

MARK/Battery

 

life

 

button.

 

Refer

 

to

 

the

 

Button

 

Descriptions

 

later

 

in

 

this

 

section.

 

10.

 

USB

 

plug

 

11.

 

Battery

 

compartment

 

(CR2032

 

x

 

2)

 

on

 

rear

 

12.

 

Wall

 

hanging

 

mount

 

(rear).

 

Mounting

 

screw

 

supplied.

 

Button

 

Descriptions

 

  

POWER

 

button

.

 

Short

 

press

 

to

 

power

 

ON

 

or

 

OFF.

 

Note

 

that

 

the

 

datalogger

 

cannot

 

be

 

switched

 

OFF

 

while

 

datalogging

 

is

 

in

 

progress.

  

 

  

START/STOP

 

button

 

(same

 

physical

 

button

 

as

 

the

 

Power

 

button

 

above).

 

Press

 

and

 

hold

 

for

 

5

 

seconds

 

to

 

start

 

or

 

stop

 

the

 

datalogger.

 

Note

 

that

 

the

 

datalogger

 

will

 

not

 

start

 

unless

 

it

 

has

 

been

 

configured

 

using

 

the

 

‘PDF

 

Logger

 

Configuration

 

Tool.exe’

 

program

 

as

 

described

 

later

 

in

 

this

 

user

 

manual.

 

 

 

Maximum

Minimum

 

Reading

 

button

.

 

At

 

any

 

time,

 

short

 

press

 

to

 

step

 

through

 

the

 

highest

 

(MX)

 

and

 

lowest

 

(MIN)

 

readings

 

recorded

 

in

 

the

 

current

 

datalogging

 

session.

 

 

 

Bookmark

 

button

.

 

Manually

 

place

 

a

 

time

stamped

 

‘bookmark’

 

in

 

the

 

datalog

 

report

 

by

 

pressing

 

and

 

holding

 

the

 

button

 

until

 

the

 

displayed

 

measurement

 

flashes

 

3

 

times.

 

Up

 

to

 

eight

 

(8)

 

bookmarks

 

can

 

be

 

saved.

 

 

Battery

 

Status

 

Note

:

 

Short

 

press

 

the

 

MARK

 

button

 

to

 

display

 

the

 

approximate

 

number

 

of

 

days

 

remaining

 

for

 

the

 

battery

 

life.

 

10

11

12

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for RHT30

Page 1: ...USER MANUAL USB Multi Function Dataloggers RHT30 Humidity Temperature Datalogger TH30 Dual Temperature Datalogger www calcert com sales calcert co 888 610 7664 0 5 10 15 20 25 30 ...

Page 2: ...PC software tool Advanced Datalogger functions including delayed start high low alarms bookmarking and password protection Automatically generate PDF and Microsoft Excel datalog reports High accuracy thermistor temperature sensor on both models with capacitive humidity sensor on the RHT30 Compact light weight design Large LCD for easy viewing Dual color red and green LED status indicator for datal...

Page 3: ... while datalogging is in progress START STOP button same physical button as the Power button above Press and hold for 5 seconds to start or stop the datalogger Note that the datalogger will not start unless it has been configured using the PDF Logger Configuration Tool exe program as described later in this user manual Maximum Minimum Reading button At any time short press to step through the high...

Page 4: ...isplayed but does not flash until after the delay time has elapsed and the logging begins Battery icon flashes once per second when battery level is critically low MX Displayed when the maximum recorded reading is selected with the MAX MIN button MN Displayed when the recorded minimum MN reading is selected with the MAX MIN button LED Status Indicator Description The dual color red green LED statu...

Page 5: ...ELAY Delay period from when START is pressed and datalogging begins 7 TEMP UNIT Temperature unit selection o C o F 8 PASSWORD Select a 16 character password for tamper protection 9 COMPANY NAME 20 Character user label for inclusion in logging report 10 SAVE Press SAVE to confirm the configuration 11 MANUAL Open the supplied PDF User Manual 12 CANCEL Abort the configuration 13 ALARM LIMIT Select th...

Page 6: ...when communication is established 4 Click on Open folder to view files to see the available files Open the program PDF Logger Configuration Tool exe 5 The default language is English select German French Italian Spanish or Portuguese as desired The generated logging report format will match the language selected 6 To review the User Manual click Manual to open the User Manual PDF file 7 The parame...

Page 7: ...old ranges for air and external probe temperature TH30 or air temperature and RH RHT30 For example if the external probe temperature range is set to 2 0 8 0o C when the measurement falls below 2o C or exceeds 8o C the LED will flash red every 10 seconds Note If an alarm occurs between two logging points the logged data will not show the alarm but the LED may still flash red every 10 seconds especi...

Page 8: ...y during datalogging press and hold the MARK button until the measured reading flashes 3 times Up to eight 8 bookmarks can be placed the bookmarks will appear in the logging report MAX MIN Readings Short press the MAX MIN button to step through the highest MX and lowest MN readings stored in memory Checking Battery Status At any time short press the MARK button to view the approximate number of da...

Page 9: ...e Datalogger capacity TH30 24000 air temperature 24000 external probe temp readings RHT30 24000 temperature 24000 humidity RH readings Sampling intervals 30 seconds and 5 10 30 60 90 120 minutes Start delay time 0 5 30 45 60 90 120 minutes and 24 hours Alarm ranges Temp 30 70o C 22 158o F Humidity 1 to 99 RH Alarm delay inhibit 0 5 30 45 60 90 120 minutes Alarm types Single Event Cumulative and Di...

Page 10: ... instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Battery Status Check To check the approximate number of days of battery life remaining short press the MARK button The display will show the number of days and the d for days XXd Cleaning Wipe the datalogger with a damp cloth do n...

Reviews: