Extech Instruments MG310 User Manual Download Page 2

2                                    MG310-en-GB_V1.0   12/15 

 

Introduction

 

Thank

 

you

 

for

 

selecting

 

the

 

MG310

 

Insulation

 

Resistance

 

Tester.

 

This

 

meter

 

measures

 

insulation

 

resistance,

 

continuity,

 

and

 

AC

 

Voltage.

 

The

 

MG310

 

is

 

CAT

 

III

 

600V

 

AC

 

and

 

ideal

 

for

 

measuring

 

insulating

 

materials

 

and

 

electrical

 

equipment

 

such

 

as

 

transformers,

 

cables,

 

switches,

 

and

 

appliances.

 

Applications

 

include

 

maintenance,

 

testing,

 

and

 

inspection.

 

Proper

 

use

 

and

 

care

 

of

 

this

 

meter

 

will

 

provide

 

many

 

years

 

of

 

reliable

 

service.

 

 

Safety

 

This

 

tester

 

is

 

designed

 

and

 

manufactured

 

in

 

compliance

 

with

 

the

 

IEC61010

 

standard.

 

This

 

user

 

manual

 

includes

 

detailed

 

information

 

related

 

to

 

the

 

safe

 

operation

 

and

 

care

 

of

 

this

 

instrument.

 

Please

 

read

 

carefully

 

before

 

using

 

the

 

instrument.

 

 

Please

 

read

 

and

 

understand

 

this

 

user

 

manual

 

before

 

using

 

the

 

device.

 

 

Always

 

use

 

the

 

device

 

as

 

specified

 

in

 

the

 

user

 

manual,

 

retain

 

the

 

manual

 

for

 

future

 

use

 

and

 

check

 

the

 

www.extech.com

 

website

 

for

 

newer

 

versions

 

of

 

the

 

user

 

manual.

 

 

Misuse

 

of

 

this

 

device

 

may

 

cause

 

personal

 

injury

 

and

 

damage

 

to

 

the

 

instrument

 

and

 

connected

 

equipment.

 

 

This

 

symbol

 

on

 

the

 

instrument

 

indicates

 

that

 

for

 

safe

 

operation

 

the

 

user

 

must

 

use

 

the

 

instrument

 

as

 

described

 

in

 

the

 

user

 

manual.

 

 

Danger

 

icons

:

 

Alert

 

to

 

conditions

 

and

 

actions

 

that

 

may

 

cause

 

serious

 

or

 

fatal

 

injury.

 

 

Warning

 

icons:

 

Alert

 

the

 

user

 

to

 

the

 

potential

 

of

 

electric

 

shock.

 

 

Caution

 

icons

:

 

Alert

 

to

 

conditions

 

and

 

actions

 

that

 

may

 

cause

 

damage

 

to

 

the

 

instrument

 

or

 

that

 

may

 

affect

 

the

 

instrument

 

accuracy.

 

 

Danger

 

 

Do

 

not

 

measure

 

circuits

 

with

 

voltages

 

greater

 

than

 

750V

 

AC.

 

 

Do

 

not

 

use

 

this

 

instrument

 

in

 

areas

 

where

 

flammable

 

conditions

 

exist.

 

 

Do

 

not

 

use

 

this

 

instrument

 

in

 

areas

 

of

 

high

 

humidity.

 

Do

 

not

 

operate

 

this

 

instrument

 

with

 

wet

 

hands.

 

 

Do

 

not

 

touch

 

conductive

 

sections

 

of

 

the

 

test

 

leads

 

when

 

taking

 

measurements.

 

 

When

 

test

 

leads

 

are

 

shorted

 

and

 

connected

 

to

 

the

 

instruments

 

do

 

not

 

press

 

the

 

TEST

 

button.

 

 

Do

 

not

 

open

 

the

 

battery

 

cover

 

during

 

tests.

 

 

Do

 

not

 

touch

 

the

 

tested

 

circuits

 

or

 

wires

 

during

 

insulation

 

measurements.

 

 

 

 

 

 

Summary of Contents for MG310

Page 1: ...USER MANUAL Insulation Resistance Tester With Continuity and AC Voltage modes Model MG310...

Page 2: ...ch com website for newer versions of the user manual Misuse of this device may cause personal injury and damage to the instrument and connected equipment This symbol on the instrument indicates that f...

Page 3: ...scharged and isolated from power circuits before taking resistance measurements If the test leads or adaptors need to be replaced due to damage replace with test leads or adaptors of the same model or...

Page 4: ...ting selection button 8 TEST button 9 Rotary function select switch Note Secure battery compartment located on rear of unit Control Buttons 1 PI DAR button Press to select PI polarization index and DA...

Page 5: ...ction switch to the OFF position when the meter is not in use 2 If OL appears in the display during a measurement the value exceeds the meter s range 3 If the batteries are weak replace them before pe...

Page 6: ...be indicated in the right most auxiliary display the symbol will flash and the caution buzzer will sound 6 Press to release the TEST button to stop the test The high voltage will switch off and the re...

Page 7: ...test DIELECTRIC ABSORPTION RATIO DAR TESTING Read and understand all operations and safety information in the Insulation Resistance IR measurement section above and in the Safety section before conti...

Page 8: ...G To avoid electric shock never measure continuity on circuits or wires that have voltage on them 1 Set the function switch to the continuity position 2 Insert the black test lead banana plug into the...

Page 9: ...not measure voltage higher than 750V AC Please use extreme caution to avoid high voltage electrical shock while operating this instrument Disconnect test leads from tested circuits and meter terminal...

Page 10: ...or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent damage to the unit BATTERY INSTALLATION W...

Page 11: ...5 5G 0 00M 5 5G 0 00M 5 5G Open circuit 250V DC 10 500V DC 10 1000V DC 10 Rated current 250K 1 00mA 1 10mA 500K 1 00mA 1 10mA 1M 1 00mA 1 10mA Short circuit Current Approx 2mA Accuracy 0 00M 99 9M 3...

Page 12: ...nd Automatic stop Test button Red lamp on TEST button indicates that test is in progress Self Test 10M 1 Continuity Check Audible signal when resistance is 20 approx Battery Six 6 1 5V AA batteries Cu...