background image

 

MA1500-en-GB_v1.4   10/18 

SAFETY NOTES 

  Do not exceed the maximum allowable input range of any function. 

  Do not apply voltage to meter when resistance function is selected. 

  Set the function switch OFF when the meter is not in use. 

  Remove the battery if meter is to be stored for longer than 60 days.

 

WARNINGS 

  Set function switch to the appropriate position before measuring. 

  When measuring volts do not switch to current/resistance modes. 

  Do not measure current on a circuit whose voltage exceeds 600V. 

  When changing ranges, always disconnect the test leads from the circuit under test. 

CAUTIONS 

  Improper use of this meter can cause damage, shock, injury or death. Read and understand 

this user manual before operating the meter. 

  Always remove the test leads before replacing the battery or fuses. 

  Inspect the condition of the test leads and the meter itself for any damage before operating the 

meter. Repair or replace any damage before use. 

  Use great care when making measurements if the voltages are greater than 25VAC rms or 

35VDC. These voltages are considered a shock hazard. 

  Always discharge capacitors and remove power from the device under test before performing 

Diode, Resistance or Continuity tests. 

  Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty 

of connection to the recessed electrical contacts. Other means should be used to ensure that 

the terminals are not "live". 

  If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 

  This device is not a toy and must not reach children’s hands. It contains hazardous objects as 

well as small parts that the children could swallow. In case a child swallows any of them, 

please contact a physician immediately 

  Do not leave batteries and packing material lying around unattended; they can be dangerous 

for children if they use them as toys 

  Expired or damaged batteries can cause cauterization on contact with the skin. Always, 

therefore, use suitable hand gloves in such cases 

  Do not short-circuited the battery. Do not throw batteries into a fire. 

 

Function 

Maximum Input 

A AC,  

1500A DC/AC 

A DC  

1500A DC/AC 

V DC, V AC 

1000V DC/AC 

Resistance, Capacitance, Frequency, Diode Test  250V DC/AC 
Type K Temperature  

30V DC, 24V AC 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for MA1500

Page 1: ...User Manual 1500Amp True RMS AC DC Clamp Meter Model MA1500 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...voided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measur...

Page 3: ...discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of...

Page 4: ...input jacks Display icons Description HOLD Data Hold APO Auto Power Off AUTO Autoranging P Peak Hold DC Direct Current AC Alternating Current MAX Max reading MIN Min reading Low battery ZERO DCA or CA...

Page 5: ...ed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation AC DC Current Measurements WARNING Disconnect the test leads before measuri...

Page 6: ...be measured Touch the red test probe tip to the other side of the device to be measured 4 Read the resistance value in the display Continuity Test 1 Set the function switch to the position 2 Insert th...

Page 7: ...MA1500 en GB_v1 4 10 18 7 If both readings are very small or 0 the device is shorted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 8: ...e Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the dev...

Page 9: ...measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO display icon will turn off 2 Press the RANGE key to step through the availabl...

Page 10: ...crew secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment door with the screw Never dispose of used batteries or rechargeable batterie...

Page 11: ...nge Resistance 400 00 0 5 9 digits 4 0000 k 1 0 4 digits 40 000 k 400 00 k 4 0000 M 2 0 10 digits 40 000 M 3 0 10 digits Capacitance 400 00 nF 3 5 reading 40 digits 4000 0 nF 3 5 reading 10 digits 40...

Page 12: ...C and VAC Crest Factor 3 0 in 400A range 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidi...