Specifications 

 

Function 

Range& Resolution 

Accuracy (% of reading) 

DC Current 

400.00 ADC 

± (2.0% +30digits) 

1500.0 ADC 

± (2.5% +30digits) 

AC Current 

True RMS (50Hz to 60 

Hz) 

400.00 AAC 

± (2.8% +30digits) 

1500.0 AAC 

All AC current ranges are specified from 5% to 100% of range 

DC Voltage 

400.00 mVDC 

± (0.1% + 5 digits) 

4.0000 VDC 

± (0.1% + 4 digits) 

40.000 VDC 

400. 00 VDC 

1000.0 VDC 

± (0.5% + 4 digits) 

AC Voltage 

True RMS (50 Hz to 

1000 Hz) 

400.00 mVAC 

± (0.8% + 40 digits)(50/60Hz) 

4.0000 VAC 

± (1.0% + 30 digits) 

40.000 VAC 

400. 00 VAC 

750.0 VAC 

All AC voltage ranges are specified from 5% to 100% of range 

Resistance 

400.00 Ω 

± (0.5% + 9 digits) 

4.0000 kΩ 

± (1.0% + 4 digits) 

40.000 kΩ 
400.00 kΩ 

4.0000 MΩ 

± (2.0% + 10 digits) 

40.000 MΩ 

± (3.0% + 10 digits) 

Capacitance 

400.00 nF 

(3.5% r 40 digits) 

4000.0 nF 

(3.5% r 10 digits) 

40.00.μF 
400.0.μF 

4.000 mF 

(5% r 10 digits) 

20.00 mF 

40.00 mF 

Not specified 

Frequency 

 

40.000 Hz 

(0.3% r 2 digits) 

 

400.00 Hz 

4.0000 kHz 
40.000 kHz 
400.00 kHz 
4.0000MHz 
40.000MHz 

Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80% 

duty cycle and > 100kHz. 

Duty Cycle 

10.0 to 95.0% 

 (1.0% r 2 digits) 

Pulse width: 100µs - 100ms, Frequency: 10Hz to 100kHz 

Temp 

(type-K) 

 

-100.0 to 1000.0

(1.0% r 2.5 

C) 

-148.0 to 1832.0

(1.0% r 4.5

F) 

(probe accuracy not included) 

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for MA1500

Page 1: ...User Manual 1500Amp True RMS AC DC Clamp Meter Model MA1500 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...voided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measur...

Page 3: ...discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of...

Page 4: ...input jacks Display icons Description HOLD Data Hold APO Auto Power Off AUTO Autoranging P Peak Hold DC Direct Current AC Alternating Current MAX Max reading MIN Min reading Low battery ZERO DCA or CA...

Page 5: ...ed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation AC DC Current Measurements WARNING Disconnect the test leads before measuri...

Page 6: ...be measured Touch the red test probe tip to the other side of the device to be measured 4 Read the resistance value in the display Continuity Test 1 Set the function switch to the position 2 Insert th...

Page 7: ...MA1500 en GB_v1 4 10 18 7 If both readings are very small or 0 the device is shorted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 8: ...e Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the dev...

Page 9: ...measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO display icon will turn off 2 Press the RANGE key to step through the availabl...

Page 10: ...crew secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment door with the screw Never dispose of used batteries or rechargeable batterie...

Page 11: ...nge Resistance 400 00 0 5 9 digits 4 0000 k 1 0 4 digits 40 000 k 400 00 k 4 0000 M 2 0 10 digits 40 000 M 3 0 10 digits Capacitance 400 00 nF 3 5 reading 40 digits 4000 0 nF 3 5 reading 10 digits 40...

Page 12: ...C and VAC Crest Factor 3 0 in 400A range 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidi...

Reviews: