Display Backlight 

Long press the backlight button to toggle the display 
backlight ON or OFF. The backlight automatically dims 
after 15 seconds. 
 

 

Maintenance 

 WARNING: To avoid electrical shock, disconnect 

the meter from any circuit and turn OFF the meter before 
opening the case. Do not operate with an open case. 

Battery Replacement 

1.

 

Turn power OFF. 

2.

 

Remove the (1) Phillips head screw that secures the 
battery compartment on the back of the meter. 

3.

 

Open the battery compartment and replace the 
two (2) 1.5V AAA batteries observing correct 
polarity. 

4.

 

Re-assemble the meter before use. 

Safety: Please dispose of batteries responsibly; never 
dispose of batteries in a fire, batteries may explode or leak. 
If the meter is not to be used for 60 days or more, remove 
the battery and store separately. 

Never dispose of used batteries or rechargeable batteries in 
household waste. 

As consumers, users are legally required to take 
used batteries to appropriate collection sites, the 
retail store where the batteries were purchased, or 
wherever batteries are sold.

 

Disposal: Do not dispose of this instrument in household 
waste. The user is obligated to take end-of-life devices to a 
designated collection point for the disposal of electrical and 
electronic equipment. 

Cleaning and Storage 

Periodically wipe the case with a damp cloth and mild 
detergent; do not use abrasives or solvents. If the meter is 
not to be used for 60 days or more, remove the batteries 
and store separately. 

 

Summary of Contents for MA130

Page 1: ...USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www extech com for user manual translations...

Page 2: ...w battery indicator and Auto Power Off feature CAT II 600V and CAT III 300V safety rating Safety Information To ensure the safe operation and service of the meter follow these instructions closely Fai...

Page 3: ...d actions that could cause DAMAGE to the meter or equipment under test Do not expose the meter to extremes in temperature or high humidity Do not expose the meter to extremes in temperature or to high...

Page 4: ...nces OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use w...

Page 5: ...d in the safety section of this manual prior to use Powering the Meter 1 Turn the rotary function switch to any position to power the meter Check the batteries if the unit fails to power ON Refer to t...

Page 6: ...s geometric center as possible 5 Do not allow a gap between the two halves of the jaw 6 Read the ACA value on the LCD Data Hold To freeze the displayed reading on the LCD long press the Data Hold H bu...

Page 7: ...esponsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Never dispose of used batteries...

Page 8: ...d Battery Two 1 5V AAA batteries Low battery display Operating Temperature 0 C to 40 C 32 F to 104 F Operating Humidity 0 C to 30 C 32 F to 86 F 75 RH 30 C to 40 C 86 F to 104 F 50 RH Storage Temperat...

Page 9: ...00 A 10mA 3 0 rdg 20 digits 200A AC 200 0 A 100mA 2 5 rdg 20 digits 200A AC Notes Frequency range 50 60Hz Maximum overload protection for clamp head terminal is 200A Accuracy stated for 10 100 of ran...

Reviews: