Introduction 

Thank you for selecting the Extech Instruments 200A AC 
Mini Clamp Meter. The MA130 measures AC Current in 
three ranges 2A, 20A, and 200A.  
 
This device is shipped fully tested and calibrated and, with 
proper use, will provide years of reliable service. Please 
visit our website (www.extech.com) to check for the 
latest version of this User Manual, Translations, Product 
Updates, Product Registration, and Customer Support. 

Features 

 

Measures AC Current in three manually selectable 
ranges 2A, 20A, and 200A 

 

2000 count Backlit LCD display 

 

Data Hold freezes displayed reading 

 

MAX function shows highest reading 

 

Compact 17mm (0.7") jaw size  

 

Low battery indicator and Auto Power Off feature 

 

CAT II-600V and CAT III-300V safety rating 

Safety Information 

To ensure the safe operation and service of the meter, 
follow these instructions closely. Failure to observe 
warnings can result in severe injury. 

WARNINGS 

WARNINGS identify hazardous conditions and 
actions that could cause BODILY HARM or DEATH. 

 

Use the meter only as specified in this User Manual to 
avoid compromising the protections provided by the 
meter. 

 

Be sure to use the switch positions, and ranges when 
taking measurements. 

 

Do not use clamp meter on a circuit with voltages 
higher than 600V. 

 

Use caution working with voltages above 30 VAC 
RMS, 42 VAC peak, or 60 VDC. These voltages pose a 
shock hazard. 

 

To avoid misleading readings that could lead to 
electric shock and injury, replace the batteries as 
soon as the low battery indicator is displayed. 

Summary of Contents for MA130

Page 1: ...USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www extech com for user manual translations...

Page 2: ...w battery indicator and Auto Power Off feature CAT II 600V and CAT III 300V safety rating Safety Information To ensure the safe operation and service of the meter follow these instructions closely Fai...

Page 3: ...d actions that could cause DAMAGE to the meter or equipment under test Do not expose the meter to extremes in temperature or high humidity Do not expose the meter to extremes in temperature or to high...

Page 4: ...nces OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use w...

Page 5: ...d in the safety section of this manual prior to use Powering the Meter 1 Turn the rotary function switch to any position to power the meter Check the batteries if the unit fails to power ON Refer to t...

Page 6: ...s geometric center as possible 5 Do not allow a gap between the two halves of the jaw 6 Read the ACA value on the LCD Data Hold To freeze the displayed reading on the LCD long press the Data Hold H bu...

Page 7: ...esponsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Never dispose of used batteries...

Page 8: ...d Battery Two 1 5V AAA batteries Low battery display Operating Temperature 0 C to 40 C 32 F to 104 F Operating Humidity 0 C to 30 C 32 F to 86 F 75 RH 30 C to 40 C 86 F to 104 F 50 RH Storage Temperat...

Page 9: ...00 A 10mA 3 0 rdg 20 digits 200A AC 200 0 A 100mA 2 5 rdg 20 digits 200A AC Notes Frequency range 50 60Hz Maximum overload protection for clamp head terminal is 200A Accuracy stated for 10 100 of ran...