Specifications
Function Range
Resolution
Accuracy
400mV 0.01mV
4V 0.0001V
40V 0.001V
400V 0.01V
±
(0.06% r 2 digits)
DC Voltage
1000V 0.1V
±
(0.1% r 2 digits)
50 to 1000Hz
400mV 0.01mV
±
(1.0% r 4 digits)
4V 0.0001V
40V 0.001V
400V 0.01V
1000V 0.1V
±
(1.0% r 3 digits)
AC Voltage
All AC voltage ranges are specified from 5% of range to 100% of range
400
μ
A 0.01
μ
A
4000
μ
A 0.1
μ
A
40mA 0.001mA
400mA 0.01mA
10A 0.001A
±
(1.0% r 3 digits)
DC Current
(20A: 30 sec max with reduced accuracy)
50 to 1000Hz
400
μ
A 0.01
μ
A
4000
μ
A 0.1
μ
A
40mA 0.001mA
400mA 0.01mA
10A 0.001A
±
(1.5% r 3 digits)
(20A: 30 sec max with reduced accuracy)
AC Current
All AC voltage ranges are specified from 5% of range to 100% of range
NOTE:
Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than 75% RH.