Extech Instruments EX530 User Manual Download Page 2

EX530-EU_ENG   V3.4    1/08 

Introduction 

Congratulations on your purchase of the Extech EX530 True RMS Autoranging Multimeter. 
This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency 
(electrical & electronic), Duty Cycle, Diode Test, and Continuity plus Thermocouple 
Temperature. It features a waterproof, rugged design for heavy duty use. Proper use and 
care of this meter will provide many years of reliable service. 

Safety 

This symbol adjacent to another symbol, terminal or operating device 

indicates that the operator must refer to an explanation in the Operating 

Instructions to avoid personal injury or damage to the meter. 

This 

WARNING

 symbol indicates a potentially hazardous situation, which 

if not avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, which 

if not avoided, may result damage to the product. 

This symbol advises the user that the terminal(s) so marked must not be 

connected to a circuit point at which the voltage with respect to earth 

ground exceeds (in this case) 1000 VAC or VDC. 

This symbol adjacent to one or more terminals identifies them as being 

associated with ranges that may, in normal use, be subjected to 

particularly hazardous voltages. For maximum safety, the meter and its 

test leads should not be handled when these terminals are energized. 

This symbol indicates that a device is protected throughout by double 

insulation or reinforced insulation. 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in 
which measures are taken to limit the transient overvoltages to an appropriate low level. 

  Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be 
supplied from the fixed installation. 

  Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 

  Note – Examples include switches in the fixed installation and some equipment for 

industrial use with permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 

Note – Examples include electricity meters and primary over-current protection equipment 

WARNING 

CAUTION 

MAX 
1000V

 

Summary of Contents for EX530

Page 1: ...User s Guide True RMS Industrial Multimeter Extech EX530...

Page 2: ...more terminals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads should not be han...

Page 3: ...lets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the equipment...

Page 4: ...TREME CAUTION when working with high voltages 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 4 NEVER connect the meter leads across a voltage source whil...

Page 5: ...tand and battery compartment are on rear of unit Symbols and Annunciators Continuity Diode test Battery status n nano 10 9 capacitance micro 10 6 amps cap m milli 10 3 volts amps A Amps k kilo 10 3 oh...

Page 6: ...display AC VOLTAGE FREQUENCY DUTY CYCLE MEASUREMENTS WARNING Risk of Electrocution The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the...

Page 7: ...ause damage to the meter and or the test leads 1 Insert black test lead banana plug into the negative COM jack 2 For current measurements up to 6000 A DC set the function switch to the yellow A positi...

Page 8: ...Touch the black test probe tip to the neutral side of the circuit Touch the red test probe tip to the hot side of the circuit 8 Apply power to the circuit 9 Read the current in the display 10 Press a...

Page 9: ...you wish to check 5 If the resistance is less than approximately 35 the audible signal will sound If the circuit is open the display will indicate OL DIODE TEST 1 Set the function switch to the green...

Page 10: ...to 482 F CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries a...

Page 11: ...IN 1 Press the MAX MIN key to activate the MAX MIN recording mode The display icon MAX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Pres...

Page 12: ...AK button again MIN will display The meter will update the dispay each time a lower negative peak occurs Press and hold the PEAK button for more than 1 second to exit PEAK Hold mode Auto Power Off fea...

Page 13: ...HE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent da...

Page 14: ...er cover 1 Disconnect the test leads from the meter 2 Remove the protective rubber holster 3 Remove the battery cover two B screws and the battery 4 Remove the six A screws securing the rear cover 5 G...

Page 15: ...Voltage All AC voltage ranges are specified from 5 of range to 100 of range 400 A 0 01 A 4000 A 0 1 A 40mA 0 001mA 400mA 0 01mA 10A 0 001A 1 0 reading 3 digits DC Current 20A 30 sec max with reduced a...

Page 16: ...001MHz 0 1 reading 1 digits 100MHz 0 01MHz Not specified Frequency electronic Sensitivity 0 8V rms min 20 to 80 duty cycle and 100kHz 5Vrms min 20 to 80 duty cycle and 100kHz 40 00 400Hz 0 01Hz 0 5 re...

Page 17: ...One 9 volt NEDA 1604 battery Fuses mA A ranges 0 5A 1000V ceramic fast blow A range 10A 1000V ceramic fast blow Operating Temperature 41 F to 104 F 5 C to 40 C Storage Temperature 4 o F to 140 o F 20...

Reviews: