5.
The “B” value will now flash. Use
the + and – keys to adjust a
digit and the MEASURE key to move from digit to digit.
6.
Once the desired value for “B” has been set, press
to
start measuring and marking.
7.
The third auxiliary display line shows the nearest stakeout
point. The primary display (bottom) shows the distance the
meter is from the nearest stakeout point.
8.
Place the meter in position. When the meter is moved slowly
along the stakeout line, the primary display (bottom) will
decrease or increase (displaying a positive number [no sign]
when the measured distance is > the stakeout distance or a
negative number [- sign] when the measured distance is <
the stakeout distance).
9.
The meter will start beeping at a distance of 0.1m (3.9”) from
the matching dimension. Note that the beep tone is different
for negative and positive values. The beeping tone will
change when you reach the stakeout distance.
10.
Mark your locations accordingly.
11.
Stop the measurement by pressing MEASURE.
20-point Datalogger
This device stores up to twenty (20) readings in memory.
1.
Take a reading as previously described. The reading will
automatically be stored in memory location 20.
2.
Take another reading, the reading that was stored in memory
location 20, previously, will move down to location 19 and the
new reading will be stored in location 20.