Introduction

 

C

ongratulations

 

on

 

your

 

purchase

 

of

 

the

 

Extech

 

AN300

 

Vane

 

Airflow

 

Anemometer.

 

This

 

instrument

 

measures

 

Air

 

Velocity,

 

Air

 

Flow

 

(volume),

 

and

 

Air

 

Temperature.

 

The

 

large,

 

easy

to

read

 

backlit

 

LCD

 

includes

 

primary

 

(upper)

 

and

 

secondary

 

(lower)

 

displays

 

plus

 

numerous

 

status

 

indicators.

 

The

 

optional

 

cone

 

and

 

funnel

 

airflow

 

adaptors

 

allow

 

for

 

quick

 

volume

 

measurements.

 

This

 

meter

 

is

 

shipped

 

fully

 

tested

 

and

 

calibrated

 

and,

 

with

 

proper

 

use,

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

Please

 

visit

 

the

 

Extech

 

Instruments

 

website

 

(www.extech.com)

 

to

 

check

 

for

 

the

 

latest

 

version

 

of

 

this

 

User

 

Guide,

 

Product

 

Updates,

 

and

 

Customer

 

Support.

 

 

CAUTIONS

 

 

Improper

 

use

 

of

 

this

 

meter

 

can

 

cause

 

damage

 

to

 

the

 

meter

 

and

 

personal

 

injury.

 

Read

 

and

 

understand

 

this

 

user

 

manual

 

before

 

operating

 

the

 

meter.

 

 

Inspect

 

the

 

condition

 

of

 

the

 

probe

 

and

 

the

 

meter

 

for

 

any

 

damage

 

before

 

operating

 

the

 

meter.

 

Repair

 

or

 

replace

 

damage

 

before

 

use.

 

 

If

 

the

 

equipment

 

is

 

used

 

in

 

a

 

manner

 

not

 

specified

 

by

 

the

 

manufacturer,

 

the

 

protection

 

provided

 

by

 

the

 

equipment

 

may

 

be

 

impaired.

 

 

This

 

device

 

should

 

not

 

be

 

made

 

available

 

to

 

children.

 

It

 

contains

 

hazardous

 

objects

 

as

 

well

 

as

 

small

 

parts

 

that

 

can

 

be

 

accidentally

 

swallowed.

 

The

 

meter’s

 

batteries

 

and

 

packing

 

material

 

can

 

also

 

be

 

dangerous

 

to

 

children.

 

 

In

 

the

 

event

 

that

 

the

 

meter

 

is

 

to

 

be

 

unused

 

for

 

an

 

extended

 

period

 

of

 

time,

 

remove

 

the

 

batteries

 

to

 

protect

 

against

 

battery

 

leakage.

 

 

Expired

 

or

 

damaged

 

batteries

 

can

 

be

 

hazardous

 

if

 

allowed

 

to

 

come

 

in

 

contact

 

with

 

skin.

 

Use

 

suitable

 

hand

 

protection

 

in

 

such

 

cases.

 

 

Do

 

not

 

short

 

circuit

 

batteries

 

or

 

put

 

batteries

 

in

 

fire.

 

 

 
 
 
 
 
 
 
 

 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for AN300

Page 1: ...USER GUIDE Large Vane CFM CMM Thermo Anemometer Model AN300 www com information itm com 1 800 561 8187 ...

Page 2: ...nd personal injury Read and understand this user manual before operating the meter Inspect the condition of the probe and the meter for any damage before operating the meter Repair or replace damage before use If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired This device should not be made available to children It contai...

Page 3: ... arrow button 4 L mode and down arrow button 5 ON OFF Power and SET button 6 HOLD MAX MIN and left arrow Enter button 7 Unit of measure symbol for lower display row 8 Unit of measure symbol for upper display row 9 Air Velocity Vane Meter Description rear 10 Air temperature sensor 11 Battery compartment www com information itm com 1 800 561 8187 ...

Page 4: ... for a timed recording session and in the SETUP mode for configuring the meter Please review the AVERAGE and SETUP mode sections for details Press and hold for 2 seconds to access the Multi Point Average and Timed Average modes the AVG icon switches ON Detailed instructions for these modes are provided later in this guide In the Setup mode press to select a category or to increase a value refer to...

Page 5: ...tional Cone and Funnel attachment icons 4 Units of measure for duct area programming 5 Vane indicator flashes very briefly on power up 6 Display HOLD icon 7 MAX mode icon 8 MIN mode icon 9 Recording icon 10 Elapsed Timer icon 11 AVG mode icon 12 Battery status icon 13 Unit of measure icons Full list shown Available units of measure icons vary by model www com information itm com 1 800 561 8187 ...

Page 6: ...en Imperial and Metric units of measure refer to the SETUP mode section 7 To measure the Air Volume of a duct first measure the duct s area see the Appendix for area calculations and then enter the area value in the meter s SETUP mode in in 2 or cm 2 After the area value has been entered press the L mode button to switch the lower display from Air Temperature to Air Volume Place the meter in the a...

Page 7: ...the AVG display icon and the associated black dot will switch ON 2 Press the HOLD button momentarily to record one reading The upper display digits will show the reading s memory location number and the lower display will show the measured value Press the HOLD button again to take and store another reading the memory location number will increment by one and the current reading will be stored in t...

Page 8: ... return to the P1 0 display 4 Press either arrow button to move to the P2 0 AREA option and follow the steps below P2 0 Area Size Selection 1 In setup mode from the P2 0 AREA display press HOLD to enter the AREA setting menu The LCD will show 99999 in the lower display with the left most digit flashing 2 Use the up arrow button change the flashing digit from 0 through 9 3 Use the down arrow button...

Page 9: ...ttery compartment before attempting to use the meter EU users are legally bound by the Battery Ordinance to return used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Other Battery Safety Reminder...

Page 10: ...0 5 4 digit LCD Sampling rate 1 reading per second approx Air velocity flow sensor Conventional angled vane arms with low friction ball bearing Temperature sensor NTC type precision thermistor Automatic Power off Auto shut off after 20 minutes to preserve battery life sleep mode Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 to 50 o C 14 to 122 o F Operating Humidity 80 RH ...

Page 11: ... the unit to Extech for repair if the E03 error message persists Air volume E03 Reading exceeds the meter s display limit Check that the AREA setting is correct in the Setup Mode E04 Air velocity error Return the meter to Extech if the error message persists Other Errors E32 Memory IC error Reboot the meter and check it again send it to Extech Instruments for repair if the error message persists N...

Page 12: ...44 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com Width W Height H Area A Width W x Height H CFM ft 3 min Air Velocity ft min x Area ft...