Introduction 

Congratulations on your purchase of Extech’s 38394 AC/DC Clamp Meter. This clamp 
meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance, Frequency, 
Diode, and Continuity. This meter is shipped fully tested and calibrated and, with proper 
use, will provide years of reliable service. 

 

Safety 

Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must 
refer to the manual for further information. 
 
 
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present 
 
 
Double insulation 

 

WARNING:

 This indicates that a potentially hazardous condition which, if not avoided, 

could result in death or serious injury.

 

 

CAUTION: 

This indicates that a potentially hazardous condition which, if not avoided, 

could result in injury or damage to the meter. 

Safety Precautions 

 

WARNING

: Improper use of this meter can cause damage, shock, injury or death. Read and 

understand this User Guide before operating the meter. 

1. 

Always remove the test leads before making current measurements 

2. 

Always remove the test leads before replacing the batteries 

3. 

Inspect the condition of the clamp jaw, test leads and the meter for any damage 
before operating the meter. Repair any damage or replace meter before use 

4. 

Do not exceed the maximum rated input limits 

5. 

Use great care when making measurements, especially when the voltages are 
greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard 

6. 

Always discharge capacitors and remove power from the DUT (device under test) 
before performing Resistance or Continuity tests 

7. 

Remove the batteries from the meter if the meter is to be stored for long periods 

8. 

Ensure that the selected meter function matches the measurement to be taken 

9. 

If the measured current is higher than the range selected for long periods, 
overheating may occur compromising the safety and the operation of the meter’s 
internal circuits 

10. 

To avoid discharge risks and erroneous readings, do not measure current on high 
voltage conductors (>600V) 

www.burntec.com

www.burntec.com

Summary of Contents for 38394

Page 1: ...User s Guide Digital AC DC Clamp Meter Model 38394 www burntec com www burntec com ...

Page 2: ...erstand this User Guide before operating the meter 1 Always remove the test leads before making current measurements 2 Always remove the test leads before replacing the batteries 3 Inspect the condition of the clamp jaw test leads and the meter for any damage before operating the meter Repair any damage or replace meter before use 4 Do not exceed the maximum rated input limits 5 Use great care whe...

Page 3: ... peak Input Limits A DC AC 600A DC AC fused Resistance 400V DC or AC peak 10 seconds Conductor Size 1 18 30mm maximum Battery type Two 2 1 5V AA batteries Range Selection Automatic ranging Display 5000 Count LCD Overload Indication 1 or 1 Low Battery Indication Battery icon Environmental conditions Installation Category III clamp Category II DMM Pollution degree 2 Altitude 2000 meters Indoor use o...

Page 4: ...ty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website www extech com for contact information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resu...

Page 5: ... unit of measure AC or DC on the left side of the LCD 3 Insert the black test lead to the COM input jack and the red test lead to the V jack 4 Connect the test leads in PARALLEL with the circuit to be measured 5 Read the displayed measurement value on the LCD display Manual Range This meter automatic selects the range However the range can be manually held and selected To manually hold the range m...

Page 6: ...ack 2 Set the Function switch to the Hz position 3 Connect the test lead tips to the device under test 4 Read the measured value on the LCD display Diode Test CAUTION Before taking measurements remove power from the circuit under test and discharge all capacitors 1 Insert the black test lead to the COM input jack and the red test lead to the V Ω input jack 2 Set the Function switch to the Ω positi...

Page 7: ...s the reference reading 3 Press the REL key to return to normal operation The REL symbol will switch off Maintenance WARNING To avoid electrical shock or damage to the meter keep moisture from entering the meter housing Also remove the test leads before opening the meter housing Cleaning Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Battery Replac...

Page 8: ...38394 V3 3 8 08 8 www burntec com www burntec com ...

Reviews: