![Express SERIES](http://html.mh-extra.com/html/express/series-h/series-h_installation-operation-and-maintenance-manual_2452458053.webp)
53
REPLACEMENT PARTS
(Table 9) - Continued
Model
Max.
Lb/Hr
Ph.
Volts
Code
Steam
Cylinder
Power
Transformer
Item #3
Contactor
Item #4
Terminal
Connector
with Wire*
Item #20
Circuit
Breaker
Item #5
Power
Distribution
Block
Item #22
H_GHH
60
3
575
7060
C65
998-9539
999-7389
690-3019
999-7414
999-8035
H_GHC
*
80
3
208
2080
C62
998-9537
999-7480 (2) 690-3046
999-7403 (2)
999-8035
H_GHE
*
80
3
230
4080
C62
998-9537
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_GHT
80
3
380
3380
C12
998-9535
999-7480
690-3046
999-7411
999-8035
H_GHW
80
3
415
4380
C12
998-9535
999-7480
690-3046
999-7411
999-8035
H_GHG
80
3
460
6080
C12
998-9537
999-7480
690-3046
999-7410
999-8035
H_GHH
80
3
575
7080
C12
998-9539
999-7389
690-3019
999-7415
999-8035
H_GHC
*
100
3
208
2100
C62
998-9537
999-7480 (2) 690-3046
999-7403 (2)
999-8035
H_GHE
*
100
3
230
4100
C62
998-9537
999-7480 (2) 690-3046
999-7403 (2)
999-8035
H_GHT
*
100
3
380
3300
C12
998-9535
999-7389 (2) 690-3046 Contact Factory
999-8035
H_GHW
100
3
415
4300
C12
998-9535 999-7389 (2) 690-3019
999-7409 (2)
999-8035
H_GHG
100
3
460
6100
C12
998-9537
999-7480
690-3046
999-7411
999-8035
H_GHH
100
3
575
7100
C12
998-9539
999-7480
690-3046
999-7416
999-8035
H_HHC
*
125
3
208
2125
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7401 (4)
999-8035
H_HHE
*
125
3
230
4125
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7401 (4)
999-9524
H_HHT
*
125
3
380
3325
C12 (2)
998-9535
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_HHW
*
125
3
415
4325
C12 (2)
998-9535
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_HHG
*
125
3
460
6125
C12 (2)
998-9537
999-7480 (2) 690-3046
999-7401 (2)
999-8035
H_HHH
125
3
575
7125
C12 (2)
998-9539
999-7389 (2) 690-3019
999-7414 (2)
999-8035
H_HHC
*
150
3
208
2150
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7402 (4)
999-9524
H_HHE
*
150
3
230
4150
C62 (2)
998-9538
999-7480 (4) 690-3046
999-7401 (4)
999-9524
H_HHT
*
150
3
380
3315
C12 (2)
998-9535
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_HHW
*
150
3
415
4315
C12 (2)
998-9535
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_HHG
*
150
3
480
6150
C12 (2)
998-9537
999-7480 (2) 690-3046
999-7402 (2)
999-8035
H_HHH
*
150
3
575
7150
C12 (2)
998-9539
999-7389 (2) 690-3019
999-7414 (2)
9998-8035
H_HHC
*
175
3
208
2175
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7403 (4)
999-9524
H_HHE
*
175
3
230
4175
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7403 (4)
999-9524
H_HHT
*
175
3
380
3317
C12 (2)
998-9535
999-7480 (4) 690-3046 Contact Factory
999-9524
H_HHW
*
175
3
415
4317
C12 (2)
998-9535
999-7480 (2) 690-3046
999-7403 (2)
999-9524
H_HHG
*
175
3
460
6175
C12 (2)
998-9537
999-7480 (2) 690-3046
999-7403 (2)
999-8035
H_HHH
*
175
3
575
7175
C12 (2)
998-9539
999-7480 (2) 690-3046
999-7416 (2)
999-8035
H_HHC
*
200
3
208
2200
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7403 (4)
999-9524
H_HHE
*
200
3
230
4200
C62 (2)
998-9537
999-7480 (4) 690-3046
999-7403 (4)
999-9524
H_HHT
*
200
3
380
3321
C12 (2)
998-9535
999-7480 (4) 690-3046 Contact Factory
999-9524
H_HHW
*
200
3
415
4321
C12 (2)
998-9535
999-7480 (4) 690-3046 Contact Factory
999-9524
H_HHG
*
200
3
460
6200
C12 (2)
998-9537
999-7480 (2) 690-3046
999-7403 (2)
999-8035
H_HHH
*
200
3
575
7200
C12 (2)
998-9539
999-7480 (2) 690-3046
999-7416 (2)
999-8035
*
= Circuit Breaker is REQUIRED per NEC 48 amp guidelines.
Design Board
Nominal Steam
Model
Series
Type
Power
Output Capacity Options
1 2 3 4 5 6 7 8 9 10
H
X
N
A
C
G
0
5
0
A
H
- Humidifier
X
- Accessory
N
- Circuit Board
A
- H690-0080
B
- H690-0106
C
- H690-0107
A
- BACnet MS/TP
C
- Modbus RTU
D
- Metasys N2
E
- Siemens FLN
Lb/Hr
005
- 5#/Hr
010
- 10#/Hr
020
- 20#/Hr
030
- 30#/Hr
040
- 40#/Hr
050
- 50#/Hr
060
- 60#/Hr
080
- 80#/Hr
100
- 100#/Hr
125
- 125#/Hr
150
- 150#/Hr
175
- 175#/Hr
200
- 200#/Hr
VOLTAGE
A
- 115V, 1 Ph.
B
- 208V, 1 Ph.
C
- 208 V, 3 Ph.
D
- 230V, 1 Ph.
E
- 230V, 3 Ph.
F
- 277V, 1 Ph.
G
- 460V, 3 Ph.
H
- 575V, 3 Ph.
M
- 460V, 1 Ph.
N
- 575V, 1 Ph.
CIRCUIT BOARD
(Table 10)