FRONT PANEL
1
2
3
7
4
5
6
8
Preparation for Operation -1
Input Cable Connection / Controller and Usage Features:
CONTROL UNITS OF FRONT AND REAR PANELS:
Before starting the machine, check input voltage, phases and frequency. Input voltage values to be used are
determined in “Specifications” sections of the user manual and in the plate located on the machine. Make
sure that the grounding of the cables connecting the machine to mains supply are suitable and sufficient
amount of current for normal operation of the machine can be supplied. Should be connected to yellow-
green cable grounding circuit.
1 - This machine has been designed as to work with 3 phase, 380 V (AC) and 50-60 Hz supply
voltage. It should only be operated on 3-phase and grounded systems.
2 - Never perform a mains supply connection and start the machine until there is a good protective
ground connection approved by a qualified electrician. Electric leakages constitute death risk for
human health.
3 - Machine has high/low voltage protection. If mains voltage is outside ±10%, thermal protection
lamp lights on and output current cuts of.