This machine is checked aginst any kind of problems before it is dispatched from the factory.
That’s why don’t let anyone who is not authorized by our company to change any equipment.
Maintenance & troubleshooting must be performed by the technical services authorized by
Kaynak Tekniği Sanayi ve Ticaret A.Ş.
To protect small parts, be careful about the air pressure while cleaning.
Maintenance must be done very carefully. If any wire, cord gets flexible or misplaced, it may be
hazardous for the operator.
Avoid water or vapour getting inside the welding machine. If the machine is effected by
humidity, it should be dried up and its isolation should be checked.
If the welding machine won't be used for extended periods, it should be placed inside the
plastic package and kept in a dry environment.
When lifting, the welding machine shouldn't be thrown randomly and be protected from blows.
1 -
2 -
3 -
4 -
5 -
6 -
7 -
Fuse trips while
the machine's main
switch is open.
Input filter board is
defective.
Refer to the service.
Machine doesn't work,
There is no output,
Fan doesn't work.
No electricity on the
line.
Check the phases' voltage which enters
the machine. Reconnect the phases.
Main input cable is
defective.
Check the main input cable. Replace
with a new one if it is necessary.
On/Off switch is
defective.
Replace the button. Contact to the service
if necessary.
Input filter or power
board is defective.
Contact to the service.
TROUBLE
POSSIBLE ERROR
SOLUTION
Caution!
For every kind of maintenance and repair operations, contact to the nearest authorized Kaynak
Teknigi Sanayi ve Ticaret A.S. technical service. Maintenance or repairs performed by unauthorized
technical services or personnel will void the manufacturer
’
s warranty.
11
Maintenance and Troubleshooting - 2
THREE-MONTH MAINTENANCE
Check if the actual current value is same with the current value set with potentiometer. Actual
current value is measured with clamp meter.