Installation
Mounting
Hanging
The fixture can be mounted in a hanging position using the mounting bracket.
Fixture must be safe mounted in accordance with the relevant regulations and
provided with a safetycord to prevent falling. For this purpose, an eyelet for
safeties is attached to the device.
Standing
The fixture can be used in an upright position, using the mounted stands. A
safe and sufficient anti-slip ground must be ensured!
NOTE
The LED module can be operated in any position.
DMX-Connection
Use specified DMX-cables to connect the units to each other and to connect them to the control-
desk. Enter the addresses and personalities to the units.
Powerconnection
230V: max. 8 fixtures in a row.
120V: max 4 fixtures in a row.
DMX512
CONTROLLER
............
DMX Addr.1
DMX Addr.
(Nx1)+1
DMX Addr.
(Nx2)+1
E-27