EX9132C-RS485
Manual
Page 18
EX9132C-RS485 • Manual Version 1.1 • 21.09.2015
www.expertdaq.com
Socket type
o
TCP Server: TCP protocol, passive open, to be connected from the TCP clients.
o
TCP Client: TCP protocol, active open, connect to the TCP server specified below.
o
UDP Client: UDP protocol, connectionless.
Remote IP address
Server IP address of the TCP Server or UDP Client (in TCP Server mode leave empty or set to “0.0.0.0”).
Remote socket port
Port of the TCP Server or UDP Client (in TCP Server mode leave empty or set to 0).
Interface of serial I/O
Interface of serial I/O is automatically detecting RS422 or RS485 (Auto Detect function). It just depends
on the connected serial devices.
Baudrate
Baud Rate: 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps
Parity, Data bits, Stop bit
Parity: None, Odd, Even, Space, Mark.
Data Bits: 5, 6, 7, 8.
Stop Bit: 1, 2.
Force off-line time
Force off-line time will close the socket port if no data is transmitting for a certain time (1 - 255 minute).
Packet Collect Time
The converter will buffer data or the serial port (Rx and Tx) until a specified time (Packet Collect Time: 1
- 999 milliseconds) no data will be transferred or the buffer is full. Then the data will be send in one
packet.