background image

7

MANUGENJSMART705 - Version 1.00

© 2020 EXOR International S.p.A. -  Subject to change without notice

The products have been designed for use in an industrial environment in compliance with the 2014/30/EU 

EMC Directive.

The products have been designed in compliance with:

EN 61000-6-4    

CISPR 22         Class B

EN 61000-6-3   

CISPR 16-2-3 

EN 61000-6-2    

EN 61000-4-2

EN 61000-6-1   

EN 61000-4-3

   EN 

61000-4-4

   EN 

61000-4-5

   EN 

61000-4-6

   EN 

61000-4-8

   

The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive 

2011/65/EU

In compliance with the above regulations the products are CE marked.

2 Standards and Approvals

Summary of Contents for JSmart705

Page 1: ...JSmart705 Operating Instructions User s Manual for JSmart705 Product MANUGENJSMART705 Version 1 00 2020 EXOR International S p A...

Page 2: ...ined in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it is provided as is without warrant...

Page 3: ...dards and Approvals 7 3 Technical Specifications 9 4 Technical Data 13 4 1 Dimensions 14 4 2 Installation Environment and Procedure 15 4 3 Safety instruction 16 5 Connections 17 5 1 Ethernet Port 17 6...

Page 4: ...elines described below is information which relates to the device installation transpor tation storage assembly use and maintenance This Operating Instruction describes the main features of the Exor o...

Page 5: ...Indications of attention are divided into three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure...

Page 6: ...e of dedicated connectors for the maximum flexibility of installation from mounting arm to a simple M22 hole The product includes environment and motion sensors to make this device a true IIoT edge de...

Page 7: ...e products have been designed in compliance with EN 61000 6 4 CISPR 22 Class B EN 61000 6 3 CISPR 16 2 3 EN 61000 6 2 EN 61000 4 2 EN 61000 6 1 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 6...

Page 8: ...w the type of unit you are using for correct usage of the information contained in the guide An example of the information reported is shown below product model name JSmart705 year week of production...

Page 9: ...o earth Immunity to conducted disturbances inducted by radiofrequency field 0 15 80 MHz 10V EN 61000 4 6 Power frequency magnetic field immunity test Enclosure 50 60Hz 30A m EN 61000 4 8 Environmental...

Page 10: ...1 Extended use in environments where the surrounding air temperature is 40 C or higher may degrade backlight quality reliability durability Viewing angles For the viewing angles values U D R L of the...

Page 11: ...glass for an exposure time of 24 hours without visible changes Betadine 10 Povidone Solution Cola Electrode Gel Paste Hydrogen Peroxide 3 Solution NaCl 0 9 Solution Coffee Dextrose 5 Glucose Solution...

Page 12: ...capacitive touch screens PCAP are suitable for operation with or without gloves A large number of gloves rubber gloves light heavy leather gloves disposable latex gloves etc are sup ported Due to the...

Page 13: ...widescreen Viewing angles horizontal Direction L Direction R Typ 70 Viewing angles vertical Direction U Typ 50 Direction D Typ 70 Dimming yes to 0 CPU ARM Cortex A9 dual core 800 MHz Operating System...

Page 14: ...NUGENJSMART705 Version 1 00 2020 EXOR International S p A Subject to change without notice 4 1 Dimensions MODEL A B C D JSmart705 105 1mm 4 13 148 3mm 5 83 16 5mm 0 64 17mm 0 66 4 Technical Data Rear...

Page 15: ...eck the resistance of the front panel to a specific compound before installation Do not use tools of any kind screwdrivers etc to operate the touch screen of the panel IP67 is guaranteed only if a JSC...

Page 16: ...RT705 Version 1 00 2020 EXOR International S p A Subject to change without notice 4 Technical Data 4 3 Safety instruction For all installation notes please refer to the Installation Guide provided wit...

Page 17: ...ce 5 Connections Reserved Pin Description 1 TX 2 TX 3 RX 4 n c 5 n c 6 RX 7 n c 8 n c 5 1 Ethernet Port Red OFF Valid link has NOT been detected ON Valid link has been detected Green ON No activity BL...

Page 18: ...the effects of noise due to electromagnetic interference on the control system The earth connection can also be made using the screws located near the connector A label helps identify the ground conn...

Page 19: ...is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures a period of 3 months of date...

Page 20: ...e equipment must be clea ned only with a soft cloth and neutral soap product Do not use solvents This device should not be used for purposes and methods other than indicated in this document and in th...

Page 21: ...creen The right side shows related information and settings Depending on the size of the HMI screen both menu and content of selected item may be shown on screen at the same time or not System Setting...

Page 22: ...ptions for basic settings of the device Language Configure language used for System Setting menu only System Show information about platform status and timers like System on time backlight on time Log...

Page 23: ...UGENJSMART705 Version 1 00 2020 EXOR International S p A Subject to change without notice 11 Unpacking and Packing Instructions To repack the unit please follow the instructions backwards Fig 11 1 JSm...

Reviews: