1.
UK – Product information
1.1
System description
RSG/RSGC
The
exodraft
RSG type fan is used as part of the fail-safe flue system for open flued gas appliances,
such as stoves and domestic boliers. The RSGC type fan is used as part of a fail-safe flue system for
closed appliances such as cookers and oil-fired and gas-fired boilers. All gas appliances must be
CE-certified.
The fan should be installed on a suitable external wall and its installation must be in
accordance with all necessary servicing, environmental and
regulatory building regulations, BS Standards, local bylaws and legal
requirements.
Flue gas temperature: min. -20 °C to max. +180 °C
Ambient temperature: min. -20 °C to max. +40 °C
1.2
Construction and design
The
exodraft
chimney fan type RSG gives a downward discharge of the flue gases through secure
grilles on the underside of the fan housing. It is made from galvanised sheet metal, fitted with a
centrifugal impeller and air flow sensors linked to a pressure differential switch (PDS), ensuring
correct airflow when the appliance is used.
The fan unit is supplied with a 6 core heat resistant silicone cable, which is 3 metres long (RSG) or 4
metres long (RSGC). The fan weigh less than 20 kg.
The RSG consists of the following main parts:
a)
fan housing
i)
cooling impeller
b)
motor
k)
screw to open hinged inner door
c)
centrifugal impeller
l)
screw to open hinged outer door
d)
pressure differential switch (PDS)
m)
outlet grill
f)
hinged outer door
n)
flow reducing plate
g)
air flow sensor (-)
o)
screw for flow reducing plate
h)
air flow sensor (+)
p)
label: "Stay clear of hot surface"
3001147 RSG-RSGC NO SE UK 150114
UK •