What can cause the power
10
1. Negative charging balance
➯
capacity loss
➯
battery
failure
• insufficient charging time (less than 12 hours) via the
on-board charger
• insufficient recharge via the lighting generator because
of low voltage (voltage losses in the on-board electricity
system or faulty/incorrectly set voltage controller)
• faulty charger
• unsuitable charger
• negative energy balance caused by too many retrofitted
electricity-consuming equipments, i.e. the energy con-
sumption is larger than the capacity charged in