2
6
|
P
a
g
e
3.
"No Flow" LED illuminated or flashing
The Excelpool System has sensed a no flow condition and has
stopped generating chlorine. Check that the flow switch is
plugged into the connector on the bottom of the
control unit and that the wire is not cut or damaged. Make sure
you have at least 12" of
straight pipe before the flow switch. If there is adequate flow and
the LED is still on, check
that the arrows on the flow switch (on top of hex) are pointing in
the direction of flow. If the
light is flashing, the flow is established and the Excelpool System
will turn on within 1
minute.
4.
"Check Salt" LED illuminated or flashing
Check salt level in pool/spa. If salt level is low, add salt according
to chart on page
10
. Before adding large quantities of salt, it is
advisable to have your salt level professionally checked.
5.
"High Salt" LED illuminated
Check salt level in pool/spa. If salt level is too high, lower salt
level by draining some of the pool water out of the pool and
replace with fresh water. Continue until the salt concentration is at
recommended levels.
6.
“Inspect Cell” LED flashing
Inspect and clean cell according to directions. When done, press
the “diagnostic” button for 3 seconds to stop the “Inspect Cell”
LED flashing.
7.
“Inspect Cell” LED illuminated
Remove and inspect the cell for scale. If the cell is scaled, follow
the directions on page
17
for cell cleaning. If the pool has the
proper amount of salt and the “Inspect Cell” LED is still
illuminated, the cell may be depleted and needs to be replaced.