background image

102761 

 

UM0097 Rev E

 

 

 
 
 
 
 
 

 

 
 
 
 

IR ILLUMINATOR 

MVS-5770 

MACHINE VISION STROBE 

 

 

OPERATION MANUAL

 

Excelitas Technologies Illumination, Inc 

35 Congress St., Salem, MA 01970  USA 

Phone: (978)745-3200  FAX: (978)745-0894 

Toll Free: (800)950-3441 in USA only 

Website  

http://www.excelitas.com

 

 

 

 

 

Summary of Contents for MVS-5770 Series

Page 1: ...INATOR MVS 5770 MACHINE VISION STROBE OPERATION MANUAL Excelitas Technologies Illumination Inc 35 Congress St Salem MA 01970 USA Phone 978 745 3200 FAX 978 745 0894 Toll Free 800 950 3441 in USA only Website http www excelitas com ...

Page 2: ...g condition that exceeds its rating can result in damage to the unit and personal injury WARNUNG Die Ausgangsspannung des MVS 5770 muss der Leistung aller damit verbundenen Komponenten angepasst werden Systemelemente Spannungen oder anderen Betriebsbedingungen auszusetzen die die Leistungswerte jener Komponenten übertreffen ist gefährlich und kann zu Schäden und Verletzungen führen ATTENTION Il fa...

Page 3: ...___ 6 4 2 EXTERNAL VOLTAGE ADJUST _______________________________________ 8 4 3 VOLTAGE SETTING VERSUS LAMP LIFE_______________________________ 8 5 0 MAINTENANCE _____________________________________________________________________9 5 1 REPAIRS ___________________________________________________________ 9 5 2 FLASHLAMP MODULE REPLACEMENT________________________________ 9 5 3 CLEANING _____________...

Page 4: ...l as a high intensity invisible IR source for applications such as license plate illumination on moving vehicles or nighttime surveillance The flashlamp system is housed in a weather resistant enclosure to provide protection against harsh environments This strobe can also be used without the IR filter for any application that requires a large area of intense illumination The unit has electrical di...

Page 5: ...ble to rough treatment during shipment Although the utmost care is taken to preserve the integrity of this item its fragile nature makes it susceptible to breakage if the container is mishandled in transit If there are any obvious signs of damage contact the carrier immediately and do not proceed with the installation It is recommended that the packaging material be retained and stored in the even...

Page 6: ...alues are nominal and subject to change without notice 2 Higher flash rates are available at lower flash energies 3 Measured at 50 points of peak intensity 4 Bandwidth depends on filter used typical Xenon spectrum is 250 1100 nm Table 2 Electrical MVS 5770 Input voltage 90 230VAC 10 50 60Hz Input current RMS 3A Trigger input 5V 25mA 10 100μsec pulse into 4N36 opto isolator with internal 150 ohm no...

Page 7: ...must be placed with in close proximity to the strobe and be with in reach of the operator It shall be marked as the disconnecting device for the strobe 3 2 SAFETY REQUIREMENTS The MVS 5770 has features related to safety For example to prevent the possibility of injury from flashlamp breakage see the section of this manual on flashlamp replacement WARNING Because this product is only one component ...

Page 8: ...rated to 300 Vac minimum and 85 C minimum It shall have an outside diameter of 30 47 inches 7 6 12 mm Tighten the cablegrip cap nut to 2 25 Nm maximum of torque The input and output cables must be supported within 12 inches 30 5 cm of each unit Select the appropriate Vref configuration Internal or External and wire per Figure 2 The system is shipped configured for Internal Vref and the optical out...

Page 9: ...102761 UM0097 Rev E 7 MVS 5770 MACHINE VISION STROBE OPERATION MANUAL Figure 3 Power Supply Input Connections Figure 2 Power Supply Input Connections ...

Page 10: ...lamp voltage may be varied from 600 VDC to a maximum of 1000 VDC V V ref x 150 Warning Do not exceed 1000VDC The flash rate must be limited so that the system does not exceed 50 watts Power energy x frequency P Ef and energy capacitance x voltage2 E CV2 4 3 VOLTAGE SETTING VERSUS LAMP LIFE Lamp life is dependent on the energy per flash For maximum lamp life lower the lamp voltage to a level that w...

Page 11: ...lumination Inc or our authorized distributors listed below Order part number FXQG 1714 3 25 Over a period of time depending on usage the xenon flashlamp may deteriorate and have to be replaced To replace the flashlamp WARNING The MVS 5700 Series strobe produces lethal voltages Ensure that input power is disconnected and storage capacitors have been discharged before beginning any inspection or cle...

Page 12: ...of the holders may cause the glass seal to fracture Always guide lamp into or out of the holders to prevent damage to the flashlamp 7 To remove the lamp grip the lamp between the thumb and index finger and gently lift the flashlamp from the Teflon Holders one end at a time See Figure 4 8 During lamp installation do not allow lamp to snap into Teflon Holders Support the lamp between thumb and index...

Page 13: ...KING AND STORAGE If the 5770 Series strobe is to be stored for a prolonged period shipped to another location or returned to the factory for repair it should be repacked in the original packaging material If this material has been discarded the unit should be repacked so as to prevent movement within the container and damage from improper handling A storage area should be dry and at a temperature ...

Page 14: ...102761 UM0097 Rev E 12 MVS 5770 MACHINE VISION STROBE OPERATION MANUAL Figure 5 Simplified Schematic MVS 5770 Series ...

Page 15: ......

Reviews: