background image

 

 

GG0261 

 

UM0034 Rev K

 

2

LS-1130 FLASHPAC OPERATION MANUAL 

1.  

INTRODUCTION 

1.1. DESCRIPTION 

The  

LS-1130 FlashPac 

 is an integrated light system that requires only external 

power and control connections for operation.  Its internal circuitry provides power to 
the discharge capacitor as well as output voltage control and triggering. 
 
The standard fiber-optic cable adapter accepts 1.00" diameter (nominal) sub-
adapters such as the MVS-14-2 or MVS-20 to accept various cable configurations 
(see Table 5).  Please consult the factory regarding other custom options. 

1.2. UNPACKING 

If the condition of the outer packaging suggests mishandling has occurred, examine 
the LS-1130 for any signs of breakage during shipment.  If there are any obvious 
signs of damage, contact the carrier immediately and do not proceed with the 
installation.  It is recommended that the packaging material be retained and stored in 
the event that the unit has to be reshipped. 

2.  

INSTALLATION 

2.1. 

MOUNTING (SEE FIGURE 1) 

Mount the unit in a protected position, without restricting air flow through its 
ventilation openings, by using two #6 clearance holes in the base of the enclosure.  
Mounting hardware is user-supplied. 

2.2. SAFETY 

REQUIREMENTS 

Use 

Input Receptacle, J1

 (on the right) as a disconnect 

device to remove any possibility of electrical input, 
particularly, when accessing the unit’s interior.  Orient the unit 
so that J1 is accessible. 

 
 
Protect the usit by coneecting user’s ground to pin 8 of  

Input Receptacle, J1. 

 
 

 
Be careful not to touch the strobe output window, which gets very hot.  
The window will break if treated in a manner inappropriate for glass. 

1 2 3 4 5

6 7 8 9

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for FlashPac LS-1130

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective owne...

Page 2: ...tas Technologies Illumination Inc 35 Congress St Salem MA 01970 USA Phone 978 745 3200 FAX 978 745 0894 Toll Free 800 950 3441 in USA only Website http www excelitas com Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...e beginning any inspection or internal adjustment WARNING The normal operation of the product involves high voltages which are potentially lethal Because this product is only one component of a system and once sold is exclusively under the control of the user it has the potential of being used in a manner outside the intended purpose of Excelitas Technologies design It is essential that the operat...

Page 4: ...ONS 8 5 5 INPUT CONNECTIONS 8 6 MAINTENANCE 9 6 1 REPAIRS 9 FLASHLAMP REPLACEMENT 9 6 3 REPACKING AND STORAGE 9 FIGURES FIGURE 1 OUTLINE AND MOUNTING DIMENSIONS 3 FIGURE 2 CHARGE TIME CURVES 5 FIGURE 3 OUTPUT VOLTAGE VS TIME 5 FIGURE 4 INPUT TRIGGER CIRCUIT 6 FIGURE 5 CONNECTIONS FOR EXTERNAL HV REFERENCE ADJUSTMENT 7 FIGURE 6 J1 INPUT CONNECTOR 8 FIGURE 7 TYPICAL CIRCUIT 8 TABLES TABLE 1 ELECTRIC...

Page 5: ...rier immediately and do not proceed with the installation It is recommended that the packaging material be retained and stored in the event that the unit has to be reshipped 2 INSTALLATION 2 1 MOUNTING SEE FIGURE 1 Mount the unit in a protected position without restricting air flow through its ventilation openings by using two 6 clearance holes in the base of the enclosure Mounting hardware is use...

Page 6: ...ES MILLIMETERS Vref ADJUST 0 73 18 5 40 1 2 PLACES 6 81 173 0 7 19 182 6 6 44 163 5 4 40 111 8 1 56 6 CLEARANCE HOLE Ø1 00 0 43 DEEP 1 44 2 50 0 93 Figure 1 Outline and Mounting Dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 7: ...ximum Line Regulation 1 Ripple 0 5 with 0 1μF 600V charge P Pmax Internal Discharge Cap PS 1130 1 0 1μF 6 PS 1130 2 0 25μF 6 PS 1130 3 0 5μF 6 PS 1130 4 1 0μF 6 PS 1130 6 0 6μF 10 PS 1130 7 0 33μF 10 Table 3 Electrical Output Trigger SCR Voltage 175V 15V Trigger Capacitor 0 1μF Max Pulse Rate 1KHz dependent on discharge capacitance Recharge Delay 200μsec typical Table 4 Mechanical Properties Input...

Page 8: ...harge time The energy per discharge is given by the expression J CV2 where Figure 2 Charge Time Curves C the discharge capacitor in microfarads μF V the voltage across C in kilovolts KV J the discharge energy in joules J Long term 1 minute or more average power must be limited to 20 watts Therefore the accumulated energy discharges joules divided by the operating period seconds must be 20 watts Th...

Page 9: ...he unit s printed circuit module When the unit is configured to use the internal reference voltage output voltage can be adjusted over its full 400 1KV range via a potentiometer RV1 which is accessed through a hole in the input panel see Figure 1 All units are shipped with JP1 in the INTERNAL position and adjusted for 600VDC 5 3 EXTERNAL ADJUSTMENT OF HV REFERENCE VOLTAGE To configure the LS 1130 ...

Page 10: ...ss than 60V Note that the power and Vref returns are connected internally Figure 5 Connections for external HV Reference Adjustment 2 1 V ref 15 28VDC POWER INPUT CASE TRIGGER RV1 MUST BE SET FULL CLOCKWISE FOR FULL RANGE OF HV ADJUSTMENT SOURCE POWER SUPPLY REF V POWER SUPPLY 4 10V REF SYSTEM GND 9 4 5 3 8 7 6 2 1 J1 INT EXT JP1 V V 7 6 3 4 1 2 3 2 3 4 WARNING Avoid looking directly at the high i...

Page 11: ...93cm long MVS 12 Backlight 2x2 in area uniformity is 5 over usable working area 37 in 94cm long MVS 13 Backlight 4x5 in area uniformity is 5 over usable working area 37 in 94cm long See Excelitas Technologies Data Sheet Machine Vision Strobe Fiber Optic Bundles 5 5 INPUT CONNECTIONS Make input connections according to Figures 6 and 7 Use 22 AWG or heavier wire for the DC power input A shielded pai...

Page 12: ...e piece out from under the optical connector 4 Loosen and remove two mounting screws and remove the optical connector 5 Grasp the defective flashlamp pull it straight out of the Lite Pac and discard it 6 Line up the leads of a new flashlamp with the corresponding holes in the Lite Pac and push the flashlamp until it is fully seated 7 Replace the optical connector screws and nosepiece over the new ...

Page 13: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: