Excelitas Technologies 019-00187R User Manual Download Page 9

 

 

035-00540R-r4 

4

 

Getting Started 

4.1

 

Packaging Contents 

Your package contains one of the following UV LED Heads, as well as a documentation CD: 

 

Model 

Optical Length 

Part Numbers 

 

 

365nm Wavelength 

395nm Wavelength 

AC7150 

150 mm 

019-00197R 

019-00198R 

AC7300 

300 mm 

019-00187R 

019-00196R 

Carefully unpack the unit and store the packing material for future use. 

4.2

 

System Requirements 

In addition to the UV LED Head, you will require the following components: 

 

Power supply 

 

Power cable 

You will also require a PLC controller unless you are using an existing controller. The PLC controller is used to 

discover the extensive functionality of the UV LED head. Integrators can access the full feature set through 
integrating with the PLC interface directly. Refer to 

Section 6.1

These may be sourced separately or may be purchased from Excelitas Technologies. Check with Excelitas 
Technologies to determine the appropriate components for your requirements. The following table provides 

the part numbers of recommended component parts, as well as a part number to order all components as a 
package. 
 

 

AC7150-365nm  AC7150-395nm  AC7300-365nm  AC7300-395nm 

UV Head 

019-00197R 

019-00198R 

019-00187R 

019-00196R 

System Controller 

019-00195R 

019-00195R 

019-00199R 

019-00199R 

DC Power Cable 

018-00559R 

018-00559R 

018-00559R 

018-00559R 

PLC Controller 

019-00214R 

019-00214R 

019-00214R 

019-00214R 

Package (all components) 

010-00334R 

010-00335R 

010-00336R 

010-00337R 

Other units are available for different purposes; check with Excelitas Technologies to determine the 
appropriate components for your requirements. 

4.3

 

Connecting the Power Supply and PLC Controller 

Note

:   

All connectors are via screw style fastener -- do not over tighten the connector screws. 

Note

:   

The following is a generic procedure, illustrated with the common components described above; 

please refer to specific documentation related to your power supply and controller. 

Tip

:  

After securing the power cable to the power supply, it is recommended to “tie-off” the female 

connector cable on to the mounting brackets

 or process rigging as a form of strain relief.

  

1.

 

Make sure the power supply unit is turned off. 

2.

 

Connect the AC power cord to the power supply 

Summary of Contents for 019-00187R

Page 1: ...rt Numbers 365nm Wavelength 395nm Wavelength AC7150 150 mm 019 00197R 019 00198R AC7300 300 mm 019 00187R 019 00196R Excelitas Canada Inc 2260 Argentia Road Mississauga ON L5N 6H7 Canada 1 905 821 260...

Page 2: ...in this manual is accurate however information in this manual is subject to change without notice and does not represent a commitment on the part of the authors Excelitas Technologies Trademarks Omni...

Page 3: ...facing with the PLC 13 6 2 Integrating Monitoring with External Circuitry 14 6 3 Interfacing with the Power Cable 14 7 Using the LED Head 15 7 1 Understanding the LED Indicators 15 7 2 Fault Status 15...

Page 4: ...gure 5 Top Front Underside of AC7150 11 Figure 6 Top Front Underside of AC7300 12 Figure 7 PLC Connector looking at UV Head 13 Figure 8 PLC digital output equivalent circuit 14 Figure 9 Power Connecto...

Page 5: ...by the integration of state of the art electronics effective thermal management and high performance optics Acoustic noise is minimised through innovative load adaptive fans that keep the LEDs operati...

Page 6: ...3 IEC62471 WARNING UV emitted from this product Avoid eye and skin exposure to unshielded product CAUTION Possibly hazardous optical radiation emitted from this product Do not stare into operating lam...

Page 7: ...stem be used in a manner not specified by Excelitas Technologies the protection provided by the equipment may be impaired The UV LED Head operation can be affected if handled incorrectly Never touch t...

Page 8: ...ogical Safety of Lamps and Lamp Systems Resulting Classification and Labelling Hazard AC7300 365 AC7300 395 Actinic UV Risk Group 3 Risk Group 3 Near UV Risk Group 3 Risk Group 3 Blue Light Risk Group...

Page 9: ...recommended component parts as well as a part number to order all components as a package AC7150 365nm AC7150 395nm AC7300 365nm AC7300 395nm UV Head 019 00197R 019 00198R 019 00187R 019 00196R System...

Page 10: ...Figure 2 6 Power up the UV LED Head per Section 4 4 then push the LED Enable button on the controller to turn power on to the LED Head 7 Adjust intensity using the up or down buttons to the right of...

Page 11: ...inute from cold state to ready state before applying UV power to the Head For more information about the indicators see Section 7 1 Understanding the LED Indicators After turning on UV power the syste...

Page 12: ...d same for all models Figure 3 UV LED Head Mounting Details Mounti ng Holes Mounting Holes 4 holes M4x6mm Right Hand and Left Hand Mounting Locations Underside Mounting Locations Mounting Holes 4 hole...

Page 13: ...mounting screws could damage the threaded mounting holes and internal components 5 3 Adjusting the Side Reflectors To improve the longitudinal uniformity at the ends of the UV light line the AC7 seri...

Page 14: ...del Weight kg lbs AC7150 1 8kg 4 0lbs AC7300 3 2kg 7 0lbs The height and depth dimensions shown in Figure 4 are the same for both models of the AC7 series Differences in length between the two models...

Page 15: ...11 035 00540R r4 Figure 5 Top Front Underside of AC7150...

Page 16: ...12 035 00540R r4 Figure 6 Top Front Underside of AC7300...

Page 17: ...operation If the user inputs a voltage below the minimum required the light source will not turn on 2 Enable High 0 0V to 0 6V Turns LEDs off Open input will default to OFF 2 4V to 24 0V ON 3 Enable L...

Page 18: ...circuit is shown in Figure 8 below Figure 8 PLC digital output equivalent circuit 6 3 Interfacing with the Power Cable Figure 9 Power Connector looking at UV Head PIN Name Description A1 A2 ve 48V DC...

Page 19: ...m Ready no critical faults Steady amber UV LED turned ON Steady red Critical fault Temperature Fault LED Fault System Error Slow flashing green POST and Initialization Input voltage is less than 46V o...

Page 20: ...ule s temperature is over the maximum limit At least one module s temperature is lower than the minimum limit or open circuit Internal Fault Ensure air intake and exhaust are unobstructed and filter i...

Page 21: ...e air filter is not clogged or obstructed If filter is clogged either clean with compressed air or replace with a new filter insert If the system powers up but does not emit UV Check that the door loc...

Page 22: ...rating When necessary clean the optical window of the UV LED Head using an optical cleaning solution Refer to Section 9 3 Cleaning the LED Head The outer lens frame of the UV LED Head includes an opti...

Page 23: ...consult the manufacturer s Materials Safety Data Sheets MSDS and your internal Health and Safety Advisor for proper handling and storage Using a new saturated tissue clean optical window by gently wi...

Page 24: ...ng Atmospheric Pressure 500 to 1060 hPa Table 4 Environmental Conditions 10 2 UV LED Head Specifications Specification AC7150 AC7300 Part number 019 00197R 019 00187R 019 00198R 019 00196R LED Peak Wa...

Page 25: ...evice or Peripheral Information to User Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are desig...

Page 26: ...r its production It may contain hazardous substances that could impact health and the environment In order to avoid the dissemination of those substances in our environment and to diminish the pressur...

Page 27: ...in particular not for compensation of consequential damages This warranty is not transferable No warranty is extended to perishable items if purchased separately or included in systems These may incl...

Page 28: ...the result of any trouble shooting steps taken Telephone the nearest Excelitas Technologies Service Centre to obtain a Return Authorization Number so that repairs may be completed quickly and efficie...

Page 29: ...68 8752 USA and Canada Fax 1 905 821 2055 http www excelitas com Pages Contact Contact_OX aspx www excelitas com omnicure Technical Assistance Techsupport excelitas com https www excelitas com ox_serv...