Excelitas Technologies 019-00187R User Manual Download Page 18

 

14 

 

035-00540R-r4 

PIN

 

Name

 

Description

 

14

 

Clear Fault/ 
LED Hours

 

High-to-low transition clears faults; low-to-high transition initiates visual 
indicator sequence of accumulated LED hours

 

15

 

Temperature 
Monitor

 

Output is a voltage proportional to the maximum UV LED heat sink 
temperature. 
Conversion Factor: 0.05V/°C.

 

Table 1 PLC Connector Pin Out 

6.2

 

Integrating Monitoring with External Circuitry 

All inputs and outputs from the PLC interface are opto-isolated. The digital outputs are implemented using 
NPN logic. The equivalent circuit is shown in 

Figure 8

 below 

 

Figure 8 PLC digital output equivalent circuit 

6.3

 

Interfacing with the Power Cable 

 

Figure 9 Power Connector (looking at UV Head) 

 

PIN

 

Name

 

Description

 

A1,A2 

 +ve 

48V DC power feed. A1 and A2 shorted together internally 

A3,A4 

-ve 

48V DC power return. A3 and A4 shorted together internally 

A5 

Chassis 

Chassis ground connection 

Table 2 Power Connector Pin Out 

 

48V Input Requirements: 

 

Voltage: 46-50V DC 

 

Current:  AC7150=7.5A; AC7300=14.5A 

 

Note:  

For safety, the AC7- series is internally fused at 15A. This fuse is not replaceable. If it is suspected 
that the internal fuse has blown, please contact 

Excelitas Technologies Service Centre

 for further 

assistance and refer to 

Sections 11 and 12

 of this manual. 

Summary of Contents for 019-00187R

Page 1: ...rt Numbers 365nm Wavelength 395nm Wavelength AC7150 150 mm 019 00197R 019 00198R AC7300 300 mm 019 00187R 019 00196R Excelitas Canada Inc 2260 Argentia Road Mississauga ON L5N 6H7 Canada 1 905 821 260...

Page 2: ...in this manual is accurate however information in this manual is subject to change without notice and does not represent a commitment on the part of the authors Excelitas Technologies Trademarks Omni...

Page 3: ...facing with the PLC 13 6 2 Integrating Monitoring with External Circuitry 14 6 3 Interfacing with the Power Cable 14 7 Using the LED Head 15 7 1 Understanding the LED Indicators 15 7 2 Fault Status 15...

Page 4: ...gure 5 Top Front Underside of AC7150 11 Figure 6 Top Front Underside of AC7300 12 Figure 7 PLC Connector looking at UV Head 13 Figure 8 PLC digital output equivalent circuit 14 Figure 9 Power Connecto...

Page 5: ...by the integration of state of the art electronics effective thermal management and high performance optics Acoustic noise is minimised through innovative load adaptive fans that keep the LEDs operati...

Page 6: ...3 IEC62471 WARNING UV emitted from this product Avoid eye and skin exposure to unshielded product CAUTION Possibly hazardous optical radiation emitted from this product Do not stare into operating lam...

Page 7: ...stem be used in a manner not specified by Excelitas Technologies the protection provided by the equipment may be impaired The UV LED Head operation can be affected if handled incorrectly Never touch t...

Page 8: ...ogical Safety of Lamps and Lamp Systems Resulting Classification and Labelling Hazard AC7300 365 AC7300 395 Actinic UV Risk Group 3 Risk Group 3 Near UV Risk Group 3 Risk Group 3 Blue Light Risk Group...

Page 9: ...recommended component parts as well as a part number to order all components as a package AC7150 365nm AC7150 395nm AC7300 365nm AC7300 395nm UV Head 019 00197R 019 00198R 019 00187R 019 00196R System...

Page 10: ...Figure 2 6 Power up the UV LED Head per Section 4 4 then push the LED Enable button on the controller to turn power on to the LED Head 7 Adjust intensity using the up or down buttons to the right of...

Page 11: ...inute from cold state to ready state before applying UV power to the Head For more information about the indicators see Section 7 1 Understanding the LED Indicators After turning on UV power the syste...

Page 12: ...d same for all models Figure 3 UV LED Head Mounting Details Mounti ng Holes Mounting Holes 4 holes M4x6mm Right Hand and Left Hand Mounting Locations Underside Mounting Locations Mounting Holes 4 hole...

Page 13: ...mounting screws could damage the threaded mounting holes and internal components 5 3 Adjusting the Side Reflectors To improve the longitudinal uniformity at the ends of the UV light line the AC7 seri...

Page 14: ...del Weight kg lbs AC7150 1 8kg 4 0lbs AC7300 3 2kg 7 0lbs The height and depth dimensions shown in Figure 4 are the same for both models of the AC7 series Differences in length between the two models...

Page 15: ...11 035 00540R r4 Figure 5 Top Front Underside of AC7150...

Page 16: ...12 035 00540R r4 Figure 6 Top Front Underside of AC7300...

Page 17: ...operation If the user inputs a voltage below the minimum required the light source will not turn on 2 Enable High 0 0V to 0 6V Turns LEDs off Open input will default to OFF 2 4V to 24 0V ON 3 Enable L...

Page 18: ...circuit is shown in Figure 8 below Figure 8 PLC digital output equivalent circuit 6 3 Interfacing with the Power Cable Figure 9 Power Connector looking at UV Head PIN Name Description A1 A2 ve 48V DC...

Page 19: ...m Ready no critical faults Steady amber UV LED turned ON Steady red Critical fault Temperature Fault LED Fault System Error Slow flashing green POST and Initialization Input voltage is less than 46V o...

Page 20: ...ule s temperature is over the maximum limit At least one module s temperature is lower than the minimum limit or open circuit Internal Fault Ensure air intake and exhaust are unobstructed and filter i...

Page 21: ...e air filter is not clogged or obstructed If filter is clogged either clean with compressed air or replace with a new filter insert If the system powers up but does not emit UV Check that the door loc...

Page 22: ...rating When necessary clean the optical window of the UV LED Head using an optical cleaning solution Refer to Section 9 3 Cleaning the LED Head The outer lens frame of the UV LED Head includes an opti...

Page 23: ...consult the manufacturer s Materials Safety Data Sheets MSDS and your internal Health and Safety Advisor for proper handling and storage Using a new saturated tissue clean optical window by gently wi...

Page 24: ...ng Atmospheric Pressure 500 to 1060 hPa Table 4 Environmental Conditions 10 2 UV LED Head Specifications Specification AC7150 AC7300 Part number 019 00197R 019 00187R 019 00198R 019 00196R LED Peak Wa...

Page 25: ...evice or Peripheral Information to User Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are desig...

Page 26: ...r its production It may contain hazardous substances that could impact health and the environment In order to avoid the dissemination of those substances in our environment and to diminish the pressur...

Page 27: ...in particular not for compensation of consequential damages This warranty is not transferable No warranty is extended to perishable items if purchased separately or included in systems These may incl...

Page 28: ...the result of any trouble shooting steps taken Telephone the nearest Excelitas Technologies Service Centre to obtain a Return Authorization Number so that repairs may be completed quickly and efficie...

Page 29: ...68 8752 USA and Canada Fax 1 905 821 2055 http www excelitas com Pages Contact Contact_OX aspx www excelitas com omnicure Technical Assistance Techsupport excelitas com https www excelitas com ox_serv...

Reviews: