13
Installer Programmable Features (cont’d)
Before using, make sure this function is supported by the Databus Interface module�
“Crank Only”
AKA “blind start” is similar to the “Tachless” settings however, it only
makes one start attempt and does not monitor engine running conditions� This is
useful for many “push-to-start” vehicles�
Feature #3 Gasoline Or Diesel Engine
Gasoline
(press “lock” button to program)
- DEFAULT
Diesel 15 Sec� Delay
(press “unlock” button to program)
Diesel 20 Sec� Delay
(press “trunk” button to program)
Diesel 30 Sec� Delay
(press “start” button to program)
This feature changes the system’s timing of the ignition and starter output sequence
for gas or diesel engines� gasoline: the starter output will occur 3 seconds after the
ignitions turn on� when in “Tachless” mode, the engine running status is determined
10 seconds after starting� Diesel: the starter output will occur 15, 20, or 30 seconds
after the ignitions turn on (allows for glow plug warming)� when in “Tachless” mode,
the engine running status will be determined 40 seconds after cranking�
Feature #4 Satellite Relay Port Green wire Function
Starter
(press “lock” button to program)
- DEFAULT
Pulse After Engine Start
(press “unlock” button to program)
Status Output
(press “trunk” button to program)
Domelight
(press “start” button to program)
This feature changes the operation of the green wire (negative) on the satellite relay
port. This gives you the flexibility to accomodate certain vehicles that require any
out-of-the-ordinary pulses or remote start timing�
Starter
setting operates as a secondary START output� This will have the same
pulse timing as the large Violet wire on the main harness�
Pulse After Start
setting will give a 0�8 second pulse immediately after the engine
starts and is running�
Status Output
setting will behave like the ignition output except it turns on 1�5
seconds earlier than the primary ignition output��
Domelight
provides domelight supervision output� It will turn on when the system is
unlocked and after turning the ignition “off”�
Feature #5 Extended Starter Cranking Time
0�7 Second
(press “lock” button to program)
- DEFAULT
1�00 Second
(press “unlock” button to program)
1�5 Seconds
(press “trunk” button to program)
2�25 Seconds
(press “start” button to program)
This feature determines the crank time of the 1st start attempt when in “Tachless”
mode. If the engine doesn’t start on the first attempt, it will retry up to 3 more times
extending the crank time by an additional 0�2 second with each attempt��