Installer Programmable Features (cont’d)
Feature #5 Satellite relay Port Green Wire Function
Starter
(press the brake pedal 1 time to program)
- DeFauLT
Pulse after engine Start
(press the brake pedal 2 times to program)
Status Output
(press the brake pedal 3 times to program)
Domelight
(press the brake pedal 4 times to program)
This feature changes the operation of the Green wire (negative) on the satellite relay
port. This gives you the flexibility to accomodate certain vehicles that require any
out-of-the-ordinary pulses or remote start timing.
Starter
setting operates as a secondary START output. This will have the same
pulse timing as the large Violet wire on the main harness.
Pulse after Start
setting will give a 0.8 second pulse immediately after the engine
starts and is running.
Status Output
setting will behave like the ignition output except it turns on 1.5
seconds earlier than the primary ignition output..
Domelight
provides domelight supervision output. It will turn on when the system is
unlocked and after turning the ignition “off”.
Feature #7 extended Starter Cranking Time
0.7 Second
(press the brake pedal 1 time to program)
- DeFauLT
1.00 Second
(press the brake pedal 2 times to program)
1.5 Seconds
(press the brake pedal 3 times to program)
2.25 Seconds
(press the brake pedal 4 times to program)
This feature determines the crank time of the 1st start attempt when in “Tachless”
mode. If the engine doesn’t start on the first attempt, it will retry up to 3 more times
extending the crank time by an additional 0.2 second with each attempt..
Feature #4 Gasoline Or Diesel engine
Gasoline
(press the brake pedal 1 time to program)
- DeFauLT
Diesel 15 Sec. Delay
(press the brake pedal 2 times to program)
Diesel 20 Sec. Delay
(press the brake pedal 3 times to program)
Diesel 30 Sec. Delay
(press the brake pedal 4 times to program)
This feature changes the system’s timing of the ignition and starter output sequence
for gas or diesel engines. Gasoline: the starter output will occur 3 seconds after the
ignitions turn on. When in “Tachless” mode, the engine running status is determined
10 seconds after starting. Diesel: the starter output will occur 15, 20, or 30 seconds
after the ignitions turn on (allows for glow plug warming). When in “Tachless” mode,
the engine running status will be determined 40 seconds after cranking.
Feature #6 Satellite relay Port Blue Wire Function
Status
(press the brake pedal 1 time to program)
- DeFauLT
Ignition
(press the brake pedal 2 times to program)
Defrost Pulse
(press the brake pedal 3 times to program)
Status
- operates like the PINK ignition output except it turns on 1.5 seconds earlier
than the PINK ignition #1 output. This is best for activating bypass kits.
Ignition
- op
-
erates with the same timing as the PINK ignition #1 output.
Defrost Pulse
will send
a pulse after start only when the cabin temperature is below freezing (32 degrees F)