12
OPTIC EXCALIBUR
English
•
Lift again the suction pipe and remove the solvent tank.
•
Now point the gun into the solvent tank and press the trigger
so as to recover the residual solvent.
•
As the pump starts idling, press the switch OFF
(0)
to
stop the equipment.
•
In case of long storage, we recommend you to suck and to
leave light mineral oil inside the pumping group and the fl exible
hose.
Follow the washing procedure before using again
the equipment.
•
Open the recirculating-safety valve (
H3
) to release the pressure
in the circuit.
•
Lift the suction pipe and replace the product tank with that
of the solvent
(ensure it is compatible with the product being
used)
.
•
Unscrew the gun nozzle
(do not forget to clean it with sol-
vent)
.
•
Press the switch (H2) ON and turn a little the pressure
control knob (H1) clockwise so as the machine works till
the motor starts.
•
Make sure the solvent recycles the washing fl uid from the
return tube.
•
Close the recirculating-safety valve (
H3
).
•
Point the gun (
H4
) into the product tank (
H5
) and, keeping
the trigger pressed, release the remaining product till a clean
solvent comes out. Now, release the trigger.
Open
Close
H3
H3
H4
H5
H3
OFF
H2
H1
-
Summary of Contents for Larius