background image

user Programmable Features

Feature #6 - Open Door Bypass of ignition Locking

On      

(press “

lock

” button to program)

 - DEFAuLT

Off      

(press “

unlock

” button to program)

This feature cancels the automatic locking or

 

unlocking of the vehicle’s doors if one of 

the doors is open when the ignition switch is turned on or off� 

Feature #5 - ignition Controlled Lock/unlock

Off             

(press “

lock

” button to program) 

- DEFAuLT 

Lock 

w/ 

ignition 

On      

(press “

unlock

” button  to program)

unlock w/ ignition Off         

(press “

trunk

” button  to program)

Lock And unlock w/ ignition    

(press “

start

” button  to program)

This feature controls the lock/unlock operations when the ignition key is turned on/off, 

Feature #1 - Remote Start Run Time

10 minutes   

(press “

lock

” button to program)

 - DEFAuLT

5 minutes   

(press “

unlock

” button to program)

 

15 minutes   

(press “

trunk

” button to program)

20 minutes   

(press “

start

” to program)

This sets the maximum amount of time that the remote start will keep the engine 

running if it is not shut down by other methods� 

Feature #3 - Confirmation Chirp Volume 

  

Low   (softest)     

(press “

lock

” button to program)

medium Low 

       (press “

unlock

” button  to program)

medium high      

  (press “

trunk

” button  to program)

 - DEFAuLT

high   (loudest)   

(press “

start

” button  to program)

This feature allows the choice different chirp volume levels, and when programming 

it, each selection will be confirmed in the chosen volume making it easy to choose the 

most suitable setting�  

Feature #4 - BROWn Wire Audible Output

Pulsed horn Low   

(press “

lock

” button to program)

 

- DEFAuLT (RS-360-EDPB)

Pulsed horn medium

   (press “

unlock

” button  to program) 

Pulsed horn high

   

(press “

trunk

” button to program)

Steady Siren

 

  (press 

start

” button  to program) 

- DEFAuLT (AL-1660-EDPB)

This changes the BROWN wire’s audible output when the alarm is triggered� Steady 

siren must be selected when using a siren (other horn outputs stay at the Medium 

setting)� The horn honk options will affect all horn honk outputs used as well as 

change the BROWN wire’s function�

Feature #2 - Flashing Light Confirmations

unlock: On, RS: On     

(press “

lock

” button to program)

 

unlock: On, RS: Flash   

(press “

unlock

” button to program)

unlock: Flash, RS: On 

  (press “

trunk

” button to program)

unlock: Flash, RS: Flash

  (press “

start

” button to program) 

- DEFAuLT

This feature affects the parking light confirmations for system unlock & remote start 

functions�  With the above options, you can select any combination of:

unlock: Flash - 

Flashes twice after unlock

unlock: On - 

Flashes twice then stays on for 30 seconds after unlock

RS: On 

- Stays on during remote start mode

RS: Flash 

- Flashes once every 1�5 seconds during remote start mode

12

Summary of Contents for AL-1660-EDPB

Page 1: ...AL 1660 EDPB RS 360 EDPB Deluxe Alarm Remote Start w BLADE Technology July 8 2014 Operation Guide Temporary cover Color cover is in a separate file 1...

Page 2: ...tection 10 Programming Transmitters 11 Programming Features 11 User Programmable Features 12 Installer Programmable Features 15 Programmable Features Matrix 19 This device complies with FCC Rules part...

Page 3: ...on Transmitter part number 1411 03 Call your dealer or visit www caralarm com to order replacement transmitters Battery replacement Remove the small screw from the lower back case and separate the tra...

Page 4: ...mote start The engine will run for the preset run time see user feature 1 Run Time Extender Press the START button one time during remote start to restart the engine run timer nOTE This can only be us...

Page 5: ...S WILL FLASH AND THE DOORS WILL LOCK OR UNLOCK DEPENDING WHICH BUTTON IS PRESSED SiLEnT LOCK unLOCK Press and release the TRUNK button twice in 5 seconds THE PARKING LIGHTS WILL FLASH AND THE SYSTEM W...

Page 6: ...king arming the alarm system THE SYSTEM WILL GIVE ONE CHIRP TO INDICATE THE SENSOR IS BYPASSED NOTE ALARM FUNCTIONS MUST BE ENABLED FOR THIS OPERATION LOW BATTERy LOW TEmP AuTOmATiC STARTinG Other Rem...

Page 7: ...minutes and then automatically turn it off The system may be locked while the engine is running Turbo Timer can be prevented from engaging or bypassed if desired by turning the engine off before engag...

Page 8: ...tes before rearming the pre warn zone Additionally if a full trigger zone is left open the system will trigger a total of 3 times before bypassing the zone Once the zone is closed it will re arm that...

Page 9: ...ocated in the window mount antenna provide a visual indication of the system s status SECURITY SYSTEM STATUS OFF The alarm is disarmed and not performing any automatic functions ON The alarm is in val...

Page 10: ...larm condition The Valet Switch may still be pressed once during this period to cancel the Anti Carjacking process If the Anti Carjacking process is not cancelled before the 60 second countdown expire...

Page 11: ...Step 1 press the Valet Switch 5 times The siren horn will briefly sound confirming that the system is ready to learn a transmitter code Step 3 Press the lock button on each transmitter one at a time T...

Page 12: ...utton to program This feature allows the choice different chirp volume levels and when programming it each selection will be confirmed in the chosen volume making it easy to choose the most suitable s...

Page 13: ...runk release in which case the alarm should also disarm This feature when on configures the system to unlock disarm when the 2nd channel is activated Feature 8 Remote Start Activation From The Remote...

Page 14: ...lock button to program Off press unlock button to program DEFAULT This feature allows an activated system to be overridden and disarmed by simply turning the ignition switch on within 10 seconds of th...

Page 15: ...rmine if the engine is running This setting looks for a voltage increase of 0 3v after cranking Tachless Lo sensitivity mode operates like the Tachless Hi setting but looks for a voltage increase of 0...

Page 16: ...button to program Double Pulse Unlock Output press trunk button to program Total Closure Lock Output press start button to program This changes the system s doorlocking outputs to suite different veh...

Page 17: ...ture 13 Alarm Functions On press lock button to program DEFAULT AL 1660 EDPB Off press unlock button to program DEFAULT RS 360 EDPB This feature converts the system into a strictly Keyless Entry Remot...

Page 18: ...ock button to program DEFAULT Arm Channel 5 press unlock button to program Channel 4 Disarm press trunk button to program Channel 4 Channel 5 press start button to program The system has outputs desig...

Page 19: ...7 Open Door Warning Upon Arming On Off Installer Feature Programming Ignition on off press valet 10 times 1 RS Activation WHITE BLUE wire 1 Pulse 2 pulses 3 pulses 4 pulses 2 PINK WHITE Wire Ignition...

Page 20: ...Back Cover Color cover is in a separate file 20...