6. Control valve does not
a. Transformer unplugged
a. Connect transformer
regenerate
b. No electric power at outlet
b. Repair outlet or use working outlet
automatically when
c. Broken drive gear or drive cap
assembly
c. Replace drive gear or drive cap
assembly
UP and DOWN buttons
d. Defective PC board
d. Replace PC board
are depressed and held
7. Control valve does not
a. Defective PC board
a. Replace PC board
regenerate
b. Set-up error
b. Check control valve set-up
procedure
automatically but does
when UP and DOWN
buttons are depressed
a. Check air – off tank. Risers in place
b. Braukman valve on.
8. Too much air in water (cloudy
small air bubbles)
c. check braukman valve internals –
clean debris etc. out
d. too much draw on intake
(micronizer) adjust to 30% draw of
pump cycle.
a.
Check
programming
9. Smell and/or Iron Filter bleeding
thru
b. Air injection set properly
c. Size of equipment correct
a. Chlorinate hot tank
10. Smell
Hot
side only
b. Optional to remove anode rod.
c. If condition persists check for
sulphur reducing bacteria
a. Unit backwashed thoroughly at
install. (backwash now)
11. Black or Grey water (cold side)
b. Check backwash control
c. Plugged backwash control
d. Kinked drain line
12. Excessive noise during backwash
a. Fasten all lines
a. Check micronizer adjustments
13. No air getting drawn into water
b. Not enough flow (check pump flow
rate)
c. Plugged air intake
d. Pressure settings should be at 30-
50 no higher.
e. (lower the pressure – increase
flow)
14. Particles in water (Media-Black)
a. Broken distributor or riser tube.