background image

nut or cap.  No not use a pipe wrench to tighten or loosen the 
Chlorosoft Water Softener/Filter nuts or caps.  Do not place 
screwdriver in slots on caps and/or tap with a hammer as this could 
damage the Chlorosoft Water Softener/Filter 
 
 
 
 
 
 

WATER SOFTENER/FILTER/FILTER  INSTALLATION 

SITE REQUIRMENTS 

 

 

  Water pressure 20 – 125 

psi 

  Current draw is 0.25 amps 

  Water temperature 5 to 

30°C or 40 to 100°F 

  A 15 foot power cord is 

furnished 

  The Water Softener/Filter 

tank should be on a firm 
level surface 

  The plug-in transformer is 

for dry location only 

  Electrical use of 115/120 

volt 60 Hz uninterrupted 
outlet 

  Batteries are not used 

 
 
 

1. 

The distance between the Chlorosoft Water Softener/Filter 
and the water drain should be as short as possible.  When 
installing your Chlorosoft Water Softener/Filter all plumbing 
must be done in accordance with local plumbing codes.  The 
Water Softener/Filter must not have a piping header that 
exceeds 3 meters (10 feet). 

 

2. 

Since Water Softener/Filter salt must be used periodically 
and be added to the Water Softener/Filter, the brine tank 
should be located where it is easily accessible. 

 

Summary of Contents for CHLOROSOFT SERIES

Page 1: ...CHLOROSOFT SERIES ELECTRONIC METERED WATER SOFTENER FILTER Installation Manual 220 Bayview Avenue Unit 18 Barrie Ontario Canada L4N 4Y8 www excaliburwater com...

Page 2: ...ur Chlorosoft Water Softener Filter on black o rings but is not necessary Avoid any type of lubricants including silicone when installing your Chlorosoft Water Softener Filter on red or clear lip seal...

Page 3: ...k should be on a firm level surface The plug in transformer is for dry location only Electrical use of 115 120 volt 60 Hz uninterrupted outlet Batteries are not used 1 The distance between the Chloros...

Page 4: ...ng assemblies When assembling the Water Softener Filter installation fitting package inlet and outlet connect the fitting to the plumbing system first and attach the Water Softener Filter nut split ri...

Page 5: ...es for air gaps and anti siphon devices 8 WATER SOFTENER FILTER BRINE TANK CONNECTION Install a 3 8 inch outside diameter polyethylene tubing from the Water Softener Filter refill elbow to the brine v...

Page 6: ...lly used to isolate the Water Softener Filter control valve from the plumbing system water pressure in order to perform Water Softener Filter control valve repairs or maintenance The bypass valve is p...

Page 7: ...outlet handles point to the centre of the bypass valve The bypass valve is isolated from the water pressure contained in the plumbing system Untreated water is supplied to the plumbing system C DIAGN...

Page 8: ...ts to the direction of flow The water is shut off to the plumbing system If water is available on the outlet side of the Water Softener Filter it is an indication of water bypass around the system WAT...

Page 9: ...slowly to expel air If water flows too rapidly there will be a loss of media out of the drain 4 When the Water Softener Filter is flowing steadily to drain without the presence of air press the Water...

Page 10: ...uto or to a number sets the maximum number of days between regenerations If valve set to off regeneration initiation is based solely on gallons used If valve is set as a number allowable range 1 to 28...

Page 11: ...lve set at NORMAL on 0 e Check control valve set up procedure regeneration time option a Control valve has just been serviced a Press NEXT and REGEN for 3 seconds or unplugged power source jack black...

Page 12: ...gear or drive cap assembly c Replace drive gear or drive cap assembly and held d Defective PC board d Replace PC board 8 Control valve does not a By pass valve in bypass position a Put bypass valve i...