Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
61
201872-003
2015-10-23
Alarms Page
This page provides an easy-to-read summary of the alarm status of both local and remote radios. The
colors on this page reflect the color of the alarms displayed on the radio front panel. However,
additional detail displays on this page to aid in quick assessment of issues and status.
Figure 37 Alarms page
Table 6 lists alarm status conditions that appear on this page.
Table 6 Alarm status indicators
Label
Status
Link System
Indicates RF link status for the entire link (all active polarizations):
•
Green Solid = Error-free connection (BER<10e-6)
•
Yellow Solid = Errored connection (10e-3>BER >10e-6)
•
Red Solid = No link (BER>10e-3)
Link V
Same as Link System, but only for the Vertical polarization link connection.
Link H
Same as Link System, but only for the Horizontal polarization link connection.
DFS V
(5GHz models only) Indicates the status of the Dynamic Frequency Selection (DFS) for the Vertical
polarization connection.
•
Green = No DFS activity, normal transmission
•
Red = Either CAC or NOP is in progress.
DFS H
(5GHz models only) Same as DFS V, but for the Horizontal polarization connection.
Collocation
Indicates the enabled/disabled status with Internal or GPS sync and current alarm status.
•
Green Solid = Sync enabled and sync input present
•
Yellow Solid = Sync enabled and missing proper sync input in flywheel operation period
•
Red Solid = Sync enabled and missing proper sync input signal and flywheel period expired