Ex-Cell ZR2700 Operation Manual Download Page 20

20- ENG

D28001

Pump oil: Refer to owners manual supplied with this unit.
Engine oil: Refer to engine manual supplied with this unit.
Some units are equipped with a low oil sensor and adequate oil must be
added or the unit will not start.

CALL

1-800-475-5660 

FOR REPAIRS AND SERVICE PART PURCHASES

QUICK FACTS

ALWAYS REFER TO THE MANUALS SUPPLIED WITH THIS UNIT

GAS

OIL

WATER

PRESSURE

ADJUSTMENT

PUMP

BY

-

PASS MODE

THERMAL

RELIEF VALVE

HOSE

ENGINE

SOAP

/

CHEMICALS

NOZZLE

MAINTENANCE

SCHEDULE

STORAGE OR
WINTERIZING

Use fresh high quality unleaded gas.
Add stabilizer to fuel tank and run engine for 5 minutes before storage.

Use only cold water.
Do not operate unit with clogged or missing water filter/screen.
Do not operate unit without adequate water supply to pump. Adequate
water supply is a minimum of 20 psi and 5 gpm.
The pressure setting is preset at the factory to achieve optimum cleaning.
If you need to lower the pressure setting, refer to the operation manual for
proper procedure. 

Pull gun trigger every 2 minutes while engine is running.
Do not allow water to freeze in pump.
For cold weather or long term storage refer to the operation manual for
proper procedure. 

Never leave unit running for more than 2 minutes without pulling gun
trigger; doing so could cause damage to pump and void warranty.

Pump is equipped with a thermal relief valve. If the water overheats, this
valve will open and allow a gush of water to escape. Once the water is
released, the valve closes allowing the pump to operate normally.

Do not allow hoses to contact the HOT engine muffler during or after use.
Never pull the hose to move the unit.
Do not adjust or attempt maintenance without consulting engine manual
or an authorized engine service center.
Add stabilizer to fuel tank and run engine for 5 minutes before storage.
Always turn on the water before starting the engine.

Use only soaps and chemicals designed for pressure washer use.

Keep nozzle unclogged.  Refer to manual for cleaning procedures.
Chemical/soap cannot be applied in high pressure setting. Only in low
setting.

Follow recommended maintenance schedule for engine & pump. Refer to
manuals.
Draw clean water through chemical inlet.
Add stabilizer to fuel tank and run engine for 5 minutes before storage.
Do not allow water to freeze in pump, gun, spray wand or hoses.
For cold weather or long term storage refer to the operation manual for
proper procedure. 

Summary of Contents for ZR2700

Page 1: ...8001 Rev 0 1 3 03 IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before operating Record all information for future refer...

Page 2: ...around flammable materials or on land covered with materials such as agricultural crops forest brush grass or other similar items then an ap proved spark arrester must be installed and is legally req...

Page 3: ...re washer in an area containing dry brush or weeds Muffler exhaust heat can damage painted surfaces melt any material sensitive to heat such as siding plastic rubber or vinyl and damage live plants Al...

Page 4: ...ont of nozzle Direct spray away from self and others Make sure hose and fittings are tightened and in good condition Never hold onto the hose or fittings during operation Do not allow hose to contact...

Page 5: ...sure washer Keep children away from the pressure washer at all times They may not be able to recognize the hazards of this product Spray directed at electrical outlets or switches or objects connected...

Page 6: ...e trigger lock when spray wand is not in service to prevent accidental operation Never permanently secure trigger in pull back open position CONSUMER GENERAL AND SERVICE INFORMATION FOR SERVICE OPTION...

Page 7: ...specific model CARTON CONTENTS Bagged Handle Bagged Parts Nozzle Cleaning Kit Engine Frame and Wheel Assembly High Pressure Hose Chemical Hose Engine Oil Spray Gun Knobs Saddle Bolts Quick Connect Spr...

Page 8: ...il in the engine from factory testing The shipping plug must be removed and replaced with the dipstick oil plug before operating pressure washer 6 Using a 17 mm wrench remove shipping plug from pump b...

Page 9: ...h pres sure nozzles for different spray patterns and change to the soap nozzle for low pressure and chemical soap applications See How To Use Spray wand paragraph in this section Chemical Hose Feeds c...

Page 10: ...inside the pump rises too high This valve will then release a gush of water in an effort to lower the temperature inside the pump Immediately after this occurs the valve will close Chemical Injection...

Page 11: ...ke sure it is secure in coupler Risk Of Injury Ensure nozzle is completely inserted in QC socket and QC snap ring is fully engaged forward before squeezing gun trigger 0 nozzle Red This nozzle deliver...

Page 12: ...ates at fluid pressures and velocities high enough to penetrate human and animal flesh which could result in amputation or other serious injury Leaks caused by loose fittings or worn or damaged hoses...

Page 13: ...E Failure to do so could cause damage to the pump 8 Start engine See Engine Owners Manual for correct procedure NOTE If the engine does not start after two pulls pull the trigger to relieve the pressu...

Page 14: ...njury or death Before performing any maintenance or repair disconnect spark plug wire let engine cool and release all water pressure The engine contains flammable fuel DO NOT smoke or work near open f...

Page 15: ...rtially clogged or restricted the pump pressure will pulsate Clean the nozzle immediately using the nozzle kit supplied and the following instructions 1 Shut off the pressure washer and turn off the w...

Page 16: ...ZING TEMPERATURES ARE EXPECTED The manufacturer recommends using EXA80 Pump Saver Winterizer EXA80 Pump Saver Winterizer may be purchased in stores where Excell pressure washers are sold If EXA80 is n...

Page 17: ...er supply Water supply must be at least 5 GPM 20 PSI Leak at high pressure hose fitting Tighten Apply sealant tape if necessary Nozzle obstructed See Spray Wand paragraph in the Maintenance section fo...

Page 18: ...valve Check and replace Loose hose connection Loose connections Tighten Piston packings worn Have replaced by AWSC Worn or broken o rings Have replaced by AWSC Pump head or tubes damaged from freezing...

Page 19: ...eceive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned used as...

Page 20: ...or long term storage refer to the operation manual for proper procedure Never leave unit running for more than 2 minutes without pulling gun trigger doing so could cause damage to pump and void warran...