592.032a 4av4 031106
GB
INSTRUCTIONS FOR
INSTALLATION AND OPERATION
This product and its accessories fulfil the
requirements of the EU's low voltage directive
(73/23/EEC and 93/68/EEC) and the directive
concerning electromagnetic compatibility
(89/336/EEC and 92/31/EEC).
INSTALLATION
The
heater
should
be
mounted
horizontally.
The heater is for use in dry rooms only.
The heater should not be mounted directly below
an electric outlet.
1. Some light vinyl floor coverings and
varnished parquet floors may become
discoloured with the long-term effect of
temperatures above 35
o
C. With these types
of floors a minimum clearance of 12 cm to
the underside of the heater is recommended.
2. Fix the two screws
c
to the wall, allowing for
the minimum clearance requirement. Hang
the heater on the scews and tighten the
screws
d
in the underside of the heater.
If you need to separate the wall bracket from
the heater, e.g. for mounting on a plaster-
board wall: Push a screwdriver down
between the back plate and the lugs on the
bracket, see diagram.
To mount the heater on the wall bracket:
Ensure that the locking lugs
e
on the wall
bracket click into the slots in the back plate
of the heater.
3. The heater may now be connected to the
mains.
OPERATING INSTRUCTIONS
Switch on the heater by pressing the switch A
(located on the back plate, to the right), and turn
the thermostat dial to 30 (max.). Light C should
come on, indicating that the heater is on and
working. When the required room temperature is
reached, slowly turn the thermostat dial B until
the light C goes out. If the thermostat is set to
✱
,
the heater offers frost protection.
NB!
The element is installed with a protective
oil covering. This will evaporate when the heater
is switched on for the first time and may emit
smoke for the first few minutes.This is normal.
SAFETY DEVICE
The heater has a built-in safety device that
disconnects the power if, for example, the heater
is accidentally covered (see below). Remove the
offending item immediately! The safety device
will automatically re-connect the power supply as
soon as the temperature in the heater returns to
normal.
DO NOT COVER THE HEATER
If the air flow through the heater is obstructed in
any way the heater will overheat and cause the
safety device to cut in and disconnect the power.
Therefore, do not dry clothes, etc., on or close to
the heater! Dust and nap can eventually block
the openings in the underside of the heater. To
avoid this, vacuum the underside at least once a
year.
Plase observe that the following
symbol means "Do not cover".
The
MAINS LEAD
is specially produced.
In the event of damage, a replacement should be
ordered from your supplier and installed by a
qualified electrician.
We reserve the right to make modifications without
notice.