4
Commissioning
4/2
4.2
Transport/set-up
The points listed in chapters 4.2.1, 4.2.2, 4.2.3 und 4.2.4 are examples only.
More detailed information can be found in the general and specific safety and accident
prevention regulations.
4.2.1
Crane transport
•
The transport vehicles can be transported by crane by attaching the lifting lugs to the fixing
points (fig. 4/1).
Use only these fixing points for lifting by crane.
•
Before crane transport remove the gas cylinder
from the transport vehicle.
•
Before crane transport, remove wire feed unit
from transport vehicle.
•
If the transport vehicle has to be moved with
the wire feed unit, ensure that the unit is
sufficiently well attached and secured.
•
The wire coil must always be removed when
moving the machine with a crane, with the wire
feed unit attached.
•
When moving the machine with a crane with
the wire feed units WELDON DRIVE 4L or
PHOENIX DRIVE 4L attached, ensure that the
press arbor (chap.2, N1) is removed from the
bracket (chap.2, M1) before attaching and
securing the unit.
Fig. 4/1
•
During crane transport no-one should be standing under the suspended load.
•
Before lifting it must be ensured that all the fixing points are securely assembled.
•
Before and after lifting, check that the snap closures between the cooling unit and
welding machine are sitting properly.
•
Before and after lifting, check that the holding plates for fixing the units to the transport
vehicle are correctly positioned.
•
The clamping plates for housing the welding machine handle must be securely
attached.
•
All loose parts such as accessories and welding torches are to be removed from the
transport vehicle before lifting.
•
Only use undamaged cables for lifting.
•
Do not raise or lower the load suddenly.
4.2.2
Assembly
Risk of injury when assembling the machines on the transport vehicles.
•
Avoid the risk of injury by careful, prudent and foresighted actions during assembly
onto the transport vehicle.
•
First fit the cooling module, then the welding machine and lastly the wire feed case.
•
For WELDON and PHOENIX DRIVE 4L wire feed units, the angle section of the A2 rail
should be fitted so that it points downwards (fig. 4/7). Otherwise there is a risk of
injuries from crushing when the wire feed units are rotating.
•
For housing WELDON and PHOENIX DRIVE 4 wire feed units, the angle section of the
A2 rail should be fitted so that it points upwards (fig. 4/9).
•
Always use original accessories and spare parts.