Design and function
Mains connection
24
099-000159-EW501
16.08.2016
5.6 Mains
connection
DANGER
Hazard caused by improper mains connection!
An improper mains connection can cause injuries or damage property!
• Only use machine with a plug socket that has a correctly fitted protective conductor.
• If a mains plug must be fitted, this may only be carried out by an electrician in accordance
with the relevant national provisions or regulations!
• Mains plug, socket and lead must be checked regularly by an electrician!
• When operating the generator always ensure it is earthed as stated in the operating
instructions. The resulting network has to be suitable for operating devices according to
protection class 1.
5.6.1 Mains
configuration
The machine may only be connected to a one-phase system with two conductors and an earthed
neutral conductor.
Figure 5-6
Legend
Item Designation
Colour
code
L Outer
conductor
brown
N Neutral
conductor
blue
PE Protective
conductor
green-yellow
The operating voltage shown on the rating plate must be consistent with the mains voltage, in
order to avoid damage to the machine > see 8 chapter!
• Insert mains plug of the switched-off machine into the appropriate socket.