Design and function
Machine cooling
099-000159-EW501
16.08.2016
21
5.2.2
Adjusting the length of the carrying strap
To demonstrate adjustment, lengthening the strap is shown in the figure. To shorten, the strap's
loops must be inched in the opposite direction.
Figure 5-1
5.3 Machine
cooling
Insufficient ventilation results in a reduction in performance and equipment damage.
• Observe the ambient conditions!
• Keep the cooling air inlet and outlet clear!
• Observe the minimum distance of 0.5 m from obstacles!
5.4 Workpiece
lead,
general
CAUTION
Risk of burning due to incorrect welding current connection!
If the welding current plugs (machine connections) are not locked or if the workpiece
connection is contaminated (paint, rust) these connections and leads can heat up and
cause burnings when touched.
• Check welding current connections on a daily basis and lock by turning to the right, when
required.
• Thoroughly clean workpiece connection and secure properly. Do not use construction parts
of the workpiece as welding current return lead!