Design and function
Remote control
52
099-005230-EW501
02.04.2014
5.10
Remote control
CAUTION
Damage due to the use of non-genuine parts!
The manufacturer's warranty becomes void if non-genuine parts are used!
• Only use system components and options (power sources, welding torches, electrode
holders, remote controls, spare parts and replacement parts, etc.) from our range of
products!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
NOTE
The remote controls are operated on the 19-pole remote control connection socket
(analogue).
Please note the relevant documentation of the accessory components.
5.11
Special parameters (advanced settings)
Special parameters (
P1
to
Pn
) are applied for customer-specific configuration of machine functions. This
allows the user maximum flexibility in optimising their requirements.
These settings are not configured directly on the machine control since a regular setting of the
parameters is generally not required. The number of selectable special parameters can deviate between
the machine controls used in the welding system (also see the relevant standard operating instructions).
If required, the special parameters can be reset to the factory settings.
5.11.1
Selecting, changing and saving parameters
NOTE
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold the "operating mode" push-button and switch the machine on again at the
same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary knob.
• Set or change the parameters by turning the "welding voltage" rotary knob.
EXIT (Exit the menu)
• Press the "gas test" push-button (switch machine off and on again).