Technical data
Taurus 405 TDM
099-005219-EW501
10.06.2013
45
8.2
Taurus 405 TDM
TIG
MIG/MAG
MMA
Setting range for welding current
5 A–400 A
Setting range for welding voltage
10.2 V–26.0 V
14.3 V–34.0 V
20.2 V–36.0 V
Duty cycle
40 °C
100%
400 A
Load alternation
10 min. (60% DC
∧
6 min. welding, 4 min. pause)
Open circuit voltage
79 V
Mains voltage (tolerances)
3 x 400 V (-25% to +20%)
Frequency
50/60 Hz
Mains fuse
(safety fuse, slow-blow)
3 x 35 A
Mains connection lead
H07RN-F4G4
Max. connected load
13.1 kVA
17.2 kVA
18.2 kVA
Recommended generator rating
25.0 kVA
cos
ϕ
0.99
Insulation class/protection
classification
H/IP 23
Ambient temperature
-25
°
C to +40
°
C
Machine/torch cooling
Fan/gas
Workpiece lead
70 mm
2
Dimensions (L x W x H)
625 mm x 300 mm x 535 mm
Weight
41 kg
EMC class
A
Constructed to standards
IEC 60974 -1, -10
/