Design and function
MMA welding
48
099-005425-EW501
14.07.2016
5.4.2
Welding task selection
Figure 5-22
5.4.3
Arcforce
Figure 5-23
Setting:
• Negative values: rutile electrode types
• Values at zero: basic electrode types
• Positive values: cellulose electrode types
5.4.4
Hotstart
The hotstart device improves the ignition of the stick electrodes using an increased ignition current.
a) =
Hotstart time
b) =
Hotstart current
I =
Welding current
t =
Time
Figure 5-24
5.4.5
Antistick
Anti-stick prevents the electrode from annealing.
If the electrode sticks in spite of the Arcforce device, the machine
automatically switches over to the minimum current within about 1
second to prevent the electrode from overheating. Check the welding
current setting and correct according to the welding task!
Figure 5-25