Functional characteristics
Machine configuration menu
46
099-00T404-EW501
02.07.2020
Display
Setting/selection
Alternative welding start
– tapping start
Available from torch mode 11 (welding stop by tapping remains active).
------- Function enabled (ex works)
------- Function disabled
Up/down speed
> see 5.1.9.3 chapter
Increase value > rapid current change
Decrease value > slow current change
Current jump
> see 5.1.9.4 chapter
Current jump setting in ampere
Machine configuration
Settings for machine functions and parameter display
Absolute value setting (ignition, secondary, end and hot start cur-
rent)
> see 4.2.1 chapter
------- Welding current setting, absolute
------- Welding current setting, as a percentage of the main current (ex works)
Non-latched operation (version C)
> see 5.1.5.6 chapter
------- Function enabled
------ Function disabled (ex works)
Welding current actual value display
> see 4.2 chapter
------- Actual value display
------- Nominal value display
Pulsed TIG welding (thermic) in the upslope and downslope pha-
ses
> see 5.1.6.1 chapter
------- Function enabled (ex works)
------ Function disabled
TIG antistick
> see 5.1.8 chapter
------- function active (factory setting).
------ function inactive.
Show warnings
> see 6.1 chapter
------ Function disabled (ex works)
------- Function enabled
Setting the system of units
------ Units of length in mm, m/min. (metric system)
------ Unit of length in inches, ipm (imperial system)
Machine configuration (second part)
Settings for machine functions and parameter display
RTF start ramp
> see 5.1.10.1 chapter
------- Welding current rises to the specified main current level in a ramp function (ex
works)
------ Welding current immediately jumps to the specified main current level
RTF response
> see 5.1.10.2 chapter
------ Linear response
------ Logarithmic responsive (ex works)
spotmatic operating mode
> see 5.1.5.5 chapter
Ignition by contact with the workpiece
------- Function enabled (ex works)
------ Function disabled
Spot time setting
> see 5.1.5.5 chapter
------- Short spot time, setting range 5 ms to 999 ms, increments of 1 ms (ex works)
------- Long spot time, setting range 0.01 s to 20.0 s, increments of 10 ms (ex works)