Functional characteristics
TIG welding
099-00T404-EW501
02.07.2020
27
Pulse balance
Figure 5-18
Pulse frequency
Figure 5-19
5.1.6.1 Pulsed welding in the upslope and downslope phases
The pulse function can also be deactivated if necessary during the up-slope and down-slope
phases (parameter
)
> see 5.6 chapter
.
Figure 5-20
5.1.6.2 Automated pulses
The automated pulsing pulse variant is only activated for DC welding in combination with the spotArc ope-
rating mode. The current-dependent pulse frequency and balance create vibrations in the weld pool that
have a positive effect on the gap bridging. The required pulse parameters are automatically defined by
the machine control. If required, the function can be disabled by pressing the pulsed welding push-button.