6
Description of M201 control
6/5
6.5
Correcting the wire feed speed
6.5.1
Correcting the wire feed speed with the remote control (Option)
Setting the correction of the wire feed speed (one knob operation) or the wire feed speed
(Operating mode manual, two knob operation) can be carried out independently of the settings on
the control.
6.5.2
Correcting the wire feed speed with the remote control on the welding torch
(Option)
•
Connect the welding torch with potentiometer to the central connection on the welding machine.
•
Plug the torch control cable into the remote control socket.
Setting the correction of the wire feed speed (one knob operation) or the wire feed speed
(Operating mode manual, two knob operation) can be carried out independently of the settings on
the control.
6.6
M110 (Option) digital V / A - Meter with Hold - Function
6.6.1
Display of actual welding data during and after welding
The digital V/A meter M110 is available as an option for the M100 and M201 controls.
With this display the Welder is kept informed of the actual current values for voltage and current
during welding. What is more, the last values for welding voltage and current measured are stored
in the display (Hold- Function).
Summary of Contents for SATURN MIG 200
Page 17: ...4 Description of the System components 4 1 4 1 System Summary...
Page 54: ......
Page 55: ...12 Ersatzteilliste Spare Parts List 12 1...
Page 65: ...14 Schaltpl ne Circuit diagrams 14 1 SATURN 250 300 M100...
Page 66: ...14 Schaltpl ne Circuit diagrams 14 2 SATURN 250 300 M100 M110...
Page 67: ...14 Schaltpl ne Circuit diagrams 14 3 SATURN 250 300 M200...
Page 68: ...14 Schaltpl ne Circuit diagrams 14 4 SATURN 250 300 M200 M110...