Technical data
Performance data
58
099-005607-EW501
20.11.2020
8.3 Performance data
8.3.1 Titan XQ 400 AC puls D
MIG/MAG
MMA
TIG
Welding current (I
2
)
5 A to 400 A
Welding voltage according to standard (U
2
) 14,3 V to 34,0 V
20,2 V to 36,0 V
10,2 V to 26,0 V
Duty cycle DC at 40° C
[1]
400 A (80 %)
370 A (100 %)
Open circuit voltage (U
0
)
82 V to 102 V
Mains voltage
3 x 380 V to 3 x 400 V
Tolerance / Frequency
-25 % to +20 % / 50/60 Hz
mains fuse
[2]
3 x 25 A
3 x 25 A
3 x 20 A
Mains connection cable
H07RN-F4G6
max. Connected load (S
1
)
water cooled
17,9 kVA
18,6 kVA
13,8 kVA
water cooled, Reinforced
18,1 kVA
14 kVA
Generator rating (Rec.)
25,1 kVA
Power consumption P
0
[3]
25 W
Maximum mains impedance (@PCC)
[4]
120 mOhm
Cos φ / efficiency
0,99 / 88 %
Protection class / Overvoltage category
Ⅰ
/
Ⅲ
Contamination level
3
Insulation class / protection classification
H / IP 23
Residual current circuit breaker
Type B (recommended)
Noise level
[5]
<70 dB(A)
Ambient temperature
[6]
-25 °C to +40 °C
Machine cooling / Torch cooling
Fan (AF) / gas or water
Workpiece lead (min.)
70 mm
2
EMC class
A
Safety marking
/ /
Standards used
See declaration of conformity (appliance documents)
[1]
Load cycle: 10 min. (60 % DC
≙
6 min. welding, 4 min. pause)
[2]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger chara-
cteristic must be used.
[3]
Power in idle mode without wire feeder.
[4]
This welding equipment does not comply with IEC 61000-3-12. When connecting a welding machine
to a public low-voltage supply system, the manufacturer or operator has to consult the electricity utili-
ties to make sure the welding machine may be connected.
[5]
Noise level during idle mode and operation under standard load according to IEC 60974
‑
1 at the ma-
ximum operating point.
[6]
Ambient temperature dependent on coolant! Observe coolant temperature range!