Rectifying faults
Error messages (power source)
62
099-005640-EW501
04.06.2020
Mains fuse triggers
Mains fuse triggers - unsuitable mains fuse
Set up recommended mains fuse
> see 8 chapter
.
7.2 Error messages (power source)
Depending on the options of the machine display, a fault is shown as follows:
Display type - machine control
Display
Graphic display
two 7-segment displays
one 7-segment display
The possible cause of the fault is signalled by a corresponding fault number (see table). In the case of an
error, the power unit shuts down.
The display of possible error numbers depends on the machine version (interfaces/functions).
• Document machine errors and inform service staff as necessary.
• If multiple errors occur, these are displayed in succession.
• Document machine errors and inform service staff as necessary.
• If multiple errors occur, these are displayed in succession.
Category
Possible cause
Remedy
a) b) c)
1
Mains overvoltage
Check the mains voltages and compare with
the connection voltages of the welding ma-
chine
2
Mains undervoltage
3
Excess temperature of
welding machine
Allow the machine to cool down (mains
switch to "1")
4
Coolant error
Fill coolant
Turn on pump shaft (coolant pump)
Check overcurrent trip of air cooling unit
5
Wire feeder, tachometer error Check the wire feeder
tachometer generator sends no signal,
motor control defective > inform Service.
6
Shielding gas error
Check shielding gas supply (for machines
with shielding gas monitoring)
7
Overvoltage on secondary
Inverter error > inform Service
8
Wire error
Separate the electrical connection between
welding wire and housing or an earthed
object
9
Fast shutdown
Rectify error on robot
(Interface for automated welding)
10
Arc interruption
Check wire feeding
(interface for automated welding)
11
Ignition error (after 5 s)
Check wire feeding
(interface for automated welding)
13
Emergency stop deactivation Check the emergency stop switch of the
interface for automated welding
14
Wire feeder detection
Check cable connections
ID number allocation error
(2DV)
Correct ID numbers