Design and function
TIG welding
099-005548-EW501
27.10.2017
45
5.5.5
Further welding parameters
The setting ranges for the parameter values are summarised in the Parameter overview
section
> see 12.1 chapter
.
• Preselection: Select TIG JOB 127
> see 5.5.3 chapter
.
ENTER
EXIT
NAVIGATION
2s
2s
Figure 5-35
Display
Setting/selection
Gas pre-flow time
Ignition current
Up-slope time
Down-slope time
End current